... ... @@ -25,66 +25,4 @@
25 25  
26 26  == Extraction Filters ==
27 27  
28 -When an extraction system is installed, its filters must be checked and replaced according to the process load and filter condition.
29 -
30 -* Check the pre-filter at least monthly.
31 -* Replace the pre-filter when it is fully or heavily contaminated.
32 -* Check the main filter at least annually.
33 -* Replace the main filter when contaminated or when extraction performance decreases.
34 -
35 -Processes that produce large quantities of dust, fumes, or aerosols may require more frequent filter replacement.
36 -
37 -(% class="box warningmessage" %)
38 -(((
39 -**Important**: Used extraction filters may contain hazardous process residues, Handle and dispose of them according to the processed material and applicable local requirements.
40 -)))
41 -
42 -== Optical Cleaning Materials ==
43 -
44 -Only suitable optical-cleaning materials may be used on laser lenses and protective glass.
45 -
46 -Approved cleaning materials may include:
47 -
48 -* Soft, lint-free optical cloths
49 -* Lens-cleaning paper
50 -* Optical lens-cleaning wipes
51 -* A small manual air blower
52 -* A manufacturer-approved optical cleaning solution
53 -* High-purity alcohol of at least 98%, where approved
54 -
55 -Never use:
56 -
57 -* Compressed air
58 -* Paper towels or abrasive cloths
59 -* Hard tools or scraping instruments
60 -* Contaminated cleaning cloths
61 -* Household glass cleaners
62 -* Unapproved solvents
63 -
64 -Apply the cleaning solution to the cloth rather than dipping the cloth into the solution
65 -
66 -For complete cleaning instructions, refer to the **[[High-Light Maintenance Article>>doc:Schilling Marking Systems High-Light.Getting Started.Maintenance.WebHome]]**.
67 -
68 -
69 -== Lubricants ==
70 -
71 -The Z-axis spindle should be inspected monthly and cleaned and lubricated when required.
72 -
73 -Use only a lubricant approved for the installed axis. Do not allow oil or grease to contact optical components, workpieces, electrical parts, or marking surfaces.
74 -
75 -
76 -== Laser Foil ==
77 -
78 -Laser foil is used to produce high-contrast markings on suitable metal surfaces. Its compatibility must be validated with the installed laser source, material, focus, and marking parameters.
79 -
80 -
81 -== Ablation Film ==
82 -
83 -Ablation film can be marked and cut using a validated laser process before being bonded to the workpiece. Different film colors and material properties may be available.
84 -
85 -For more information, refer to[[ **Accessories and Options**>>doc:Schilling Marking Systems High-Light.Overview.Accessories and Options.WebHome]].
86 -
87 -
88 -= Replacement And Service Parts =
89 -
90 -Some High-Light components influence laser containment, electrical safety, or machine accuracy. These components must only be replaced by Schilling Marki
28 +When an ext