Änderungen von Dokument Accessories and Options

Zuletzt geändert von jadomatis am 2026/09/02 08:23

Von Version 5.2
bearbeitet von jadomatis
am 2026/09/02 08:09
Änderungskommentar: Es gibt keinen Kommentar für diese Version
Auf Version 6.1
bearbeitet von jadomatis
am 2026/09/02 08:11
Änderungskommentar: Uploaded new attachment "1788329065581-145.png", version {1}

Zusammenfassung

Details

Seiteneigenschaften
Inhalt
... ... @@ -14,7 +14,7 @@
14 14  Use a suitable extraction system when marking plastics or when the process removes larger amounts of material, such as from anodized, painted, or coated parts. Extraction units are available in different sizes and performance classes and can also be retrofitted to a High-Light system. Select the unit and filters for the material, process emissions, and expected workload.
15 15  
16 16  
17 -Rotation Axis
17 += Rotation Axis =
18 18  
19 19  [[image:1788328693374-151.png||data-xwiki-image-style-alignment="end" height="165" width="253"]]
20 20  
... ... @@ -26,8 +26,8 @@
26 26  * Allow quick changeover with an optional quick-clamping chuck.
27 27  
28 28  The rotation axis is controlled through the marking software supplied with the High-Light. It connects through a serial interface and allows the system to produce circumferential markings on suitable cylindrical parts. Confirm the axis size, chuck, workpiece weight, diameter, and software configuration before use.
29 +\\
29 29  
30 -
31 31  = Fixture Device =
32 32  
33 33  [[image:1788328749826-548.png||data-xwiki-image-style-alignment="end" height="211" width="281"]]
... ... @@ -39,13 +39,11 @@
39 39  * Adapt the loading position to the workpiece geometry.
40 40  
41 41  A workpiece-specific fixture ensures that each part is loaded in the correct position and marked in the same location. Fixtures simplify loading, reduce setup time, and lower the risk of positioning errors. Standard fixtures are available, and custom fixtures can be produced for individual workpiece geometries.
42 +\\
42 42  
43 -
44 -
45 -
46 46  = Objectives and Lenses =
47 47  
48 -[[image:1788328800970-646.png||data-xwiki-image-style-alignment="end"]]
46 +[[image:1788328800970-646.png||data-xwiki-image-style-alignment="end" height="217" width="197"]]
49 49  
50 50  **Purpose**
51 51  
... ... @@ -60,9 +60,10 @@
60 60  **Compatibility: **Use only an objective approved for the installed High-Light laser source and wavelength. Fiber/MOPA, UV, and ultrashort-pulse configurations are not automatically optically interchangeable.
61 61  )))
62 62  
63 -= Laser Safety Goggles =
61 +=
62 +\\Laser Safety Goggles =
64 64  
65 -[[image:1788328844140-263.png]]
64 +[[image:1788328844140-263.png||data-xwiki-image-style-alignment="end" height="185" width="294"]]
66 66  
67 67  **Purpose**
68 68  
... ... @@ -71,5 +71,3 @@
71 71  * Provide a comfortable fit for personnel required to wear them.
72 72  
73 73  During normal operation, the High-Light is used as an enclosed Laser Class 1 workstation. Laser safety goggles do not replace the protective enclosure, door interlocks, or other safety devices. If an authorized procedure requires operation outside the protective enclosure, every person in the controlled laser area must wear certified eyewear selected for the installed wavelength and required optical density.
74 -
75 -**Safety warning: **The goggles shown in the manual are described for fiber and diode lasers. Do not assume that they are suitable for a 355 nm UV source or a 1,030 nm ultrashort-pulse source. Selection must be approved by the responsible laser safety specialist.
1788329065581-145.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.jadomatis
Größe
... ... @@ -1,0 +1,1 @@
1 +42.7 KB
Inhalt