Changes for page Accessories and Options

Last modified by jadomatis on 2026/09/02 08:23

From version 4.2
edited by jadomatis
on 2026/09/02 08:07
Change comment: There is no comment for this version
To version 5.2
edited by jadomatis
on 2026/09/02 08:09
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -2,7 +2,7 @@
2 2  
3 3  = Extraction System =
4 4  
5 -[[image:1788328614945-364.png||data-xwiki-image-style-alignment="end" height="274" width="160"]]
5 +[[image:1788328614945-364.png||data-xwiki-image-style-alignment="end" height="210" width="123"]]
6 6  
7 7  **Purpose**
8 8  
... ... @@ -14,13 +14,8 @@
14 14  Use a suitable extraction system when marking plastics or when the process removes larger amounts of material, such as from anodized, painted, or coated parts. Extraction units are available in different sizes and performance classes and can also be retrofitted to a High-Light system. Select the unit and filters for the material, process emissions, and expected workload.
15 15  
16 16  
17 +Rotation Axis
17 17  
18 -
19 -
20 -
21 -
22 -= Rotation Axis =
23 -
24 24  [[image:1788328693374-151.png||data-xwiki-image-style-alignment="end" height="165" width="253"]]
25 25  
26 26  **Purpose**
... ... @@ -33,12 +33,9 @@
33 33  The rotation axis is controlled through the marking software supplied with the High-Light. It connects through a serial interface and allows the system to produce circumferential markings on suitable cylindrical parts. Confirm the axis size, chuck, workpiece weight, diameter, and software configuration before use.
34 34  
35 35  
36 -
37 -
38 -
39 39  = Fixture Device =
40 40  
41 -[[image:1788328749826-548.png||data-xwiki-image-style-alignment="end"]]
33 +[[image:1788328749826-548.png||data-xwiki-image-style-alignment="end" height="211" width="281"]]
42 42  
43 43  **Purpose**
44 44  
... ... @@ -51,8 +51,6 @@
51 51  
52 52  
53 53  
54 -
55 -
56 56  = Objectives and Lenses =
57 57  
58 58  [[image:1788328800970-646.png||data-xwiki-image-style-alignment="end"]]
... ... @@ -69,3 +69,17 @@
69 69  (((
70 70  **Compatibility: **Use only an objective approved for the installed High-Light laser source and wavelength. Fiber/MOPA, UV, and ultrashort-pulse configurations are not automatically optically interchangeable.
71 71  )))
62 +
63 += Laser Safety Goggles =
64 +
65 +[[image:1788328844140-263.png]]
66 +
67 +**Purpose**
68 +
69 +* Provide personal protection for an authorized open-laser setup.
70 +* Match the protection range and optical density to the exact laser source.
71 +* Provide a comfortable fit for personnel required to wear them.
72 +
73 +During normal operation, the High-Light is used as an enclosed Laser Class 1 workstation. Laser safety goggles do not replace the protective enclosure, door interlocks, or other safety devices. If an authorized procedure requires operation outside the protective enclosure, every person in the controlled laser area must wear certified eyewear selected for the installed wavelength and required optical density.
74 +
75 +**Safety warning: **The goggles shown in the manual are described for fiber and diode lasers. Do not assume that they are suitable for a 355 nm UV source or a 1,030 nm ultrashort-pulse source. Selection must be approved by the responsible laser safety specialist.
1788328844140-263.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.jadomatis
Size
... ... @@ -1,0 +1,1 @@
1 +82.6 KB
Content