Zuletzt geändert von jadomatis am 2026/09/02 07:32

Zeige letzte Bearbeiter
1 **Description**: Learn the technical specifications of High-Light laser marking machine.
2
3 {{toc/}}
4
5 ----
6
7 = Introduction =
8
9 The High-Light is an enclosed industrial laser marking workstation designed for processing large workpieces and extended marking areas. It combines an electrically operated safety enclosure with software-controlled X-, Y-, and Z-axes.
10
11 The system is available with fiber, MOPA fiber, UV and ultrashort-pulse laser sources. The exact technical data depend on the installed laser configuration.
12
13 = Standard Configuration =
14
15 The standard High-Light configuration includes:
16
17 * Schilling laser source
18 * Enclosed Laser Class 1 workstation
19 * Large laser protection window, approximately 750 x 300 mm
20 * Perforated fixture plate
21 * Automatic electric U-shaped lifting door with internal safety monitoring
22 * Fully enclosed wheeled base frame
23 * Integrated pilot laser
24 * Integrated focus laser
25 * Software-controlled X/Y/Z axis system
26 * Z-axis travel of approximately 300 mm
27 * X/Y-axis travel of approximately 460 x 260 mm
28 * Axis motors and control system
29 * Swivel arm with keyboard and monitor holders
30 * AnyMarker Designer marking software
31 * Optional rotation axis
32
33 The supplied equipment and software may vary according to the ordered configuration.
34
35 = General Technical Data =
36
37 (% class="table-condensed table-striped" %)
38 |=Specification|=High-Light
39 |Standard marking area|Approximately 570 x 270 mm
40 |Alternative marking areas|Available on request
41 |Electrical axes|X-, Y, and Z-axis
42 |Optional axis|Rotation axis
43 |X/Y travel|Approximately 460 x 260 mm
44 |Z-axis travel|Approximately 300 mm
45 |Safety classification|Laser Class 1 with intact protective enclosure
46 |Door|Automatic electric U-shaped lifting door
47 |Door monitoring|Internal safety interlock
48 |Positioning system|Pilot laser
49 |Focusing aid|Focus laser
50 |Standard software|AnyMarker Designer
51 |Power connection|230 V
52 |Network connection|Ethernet
53 |External interface|I/O interface
54 |Extraction connection|Integrated connection point
55 |Warranty period|24 months from delivery date
56
57 (% class="box infomessage" %)
58 (((
59 The laser source inside the machine can generate Class 4 laser radiation. The complete workstation operates as Laser Class 1 only while all protective panels, doors, interlocks, seals, and laser protection windows are intact and functioning properly.
60 )))
61
62 = Fiber And MOPA Fiber Laser Models =
63
64 The fiber-laser configurations use air-cooled laser source with a fiber length of 3 m.
65
66 (% class="table-condensed table-striped" %)
67 |=Model|=Output power|=Pulse energy|=(% style="width: 132px;" %)Beam quality|=(% style="width: 117px;" %)Pulse frequency|=(% style="width: 174px;" %)Pulse duration|=(% style="width: 218px;" %)Laser power consumption
68 |High-Light F20|20 W|Approx. 1 mJ|(% style="width:132px" %)M² < 1.5|(% style="width:117px" %)30-60kHz|(% style="width:174px" %)100 ns|(% style="width:218px" %)< 200 W
69 |High-Light F30|30 W|Approx. 1 mJ|(% style="width:132px" %)M² < 1.5|(% style="width:117px" %)20-60kHz|(% style="width:174px" %)100 ns|(% style="width:218px" %)< 300 W
70 |High-Light F50|50 W|Approx. 1 mJ|(% style="width:132px" %)M² < 1.8|(% style="width:117px" %)50-100kHz|(% style="width:174px" %)100 ns|(% style="width:218px" %)< 340 W
71 |High-Light M20|20 W|Approx. 0.7 mJ|(% style="width:132px" %)M² < 1.3|(% style="width:117px" %)1-2000kHz|(% style="width:174px" %)2-550 ns|(% style="width:218px" %)< 150 W
72 |High-Light M30|30 W|Approx. 1 mJ|(% style="width:132px" %)M² < 1.3|(% style="width:117px" %)1-2000kHz|(% style="width:174px" %)2-550 ns|(% style="width:218px" %)< 170 W
73 |High-Light M100|100 W|Approx. 1.5 mJ|(% style="width:132px" %)M² < 1.6|(% style="width:117px" %)1-2000kHz|(% style="width:174px" %)10-350 ns|(% style="width:218px" %) 500 W
74 |High-Light M200|200 W|Approx. 1.5 mJ|(% style="width:132px" %)M² < 1.6|(% style="width:117px" %)1-4000kHz|(% style="width:174px" %)10-350 ns|(% style="width:218px" %) 800 W
75 |High-Light M250|250 W|Approx. 1.5 mJ|(% style="width:132px" %)M² < 1.8|(% style="width:117px" %)1-4000kHz|(% style="width:174px" %)10-350 ns|(% style="width:218px" %)1000 W
76
77
78
79 = Fiber And MOPA Configuration Data =
80
81 (% class="table-striped" %)
82 |=Specification|=Value
83 |Wavelength|Approximately 1060-1070 nm
84 |Cooling|Air
85 |Fiber length|3 m
86 |Standard marking area|Approximately 570 x 270 mm
87 |Maximum workpiece size|Approximately 800 x 500 x 300 mm
88 |Enclosure dimensions|Approximately 1040 x 860 x 2025 mm
89 |Electrical axes|X/Y/Z
90 |Optional axis|Rotation axis
91 |Positioning and focus lasers|Included
92
93 (% class="box infomessage" %)
94 (((
95 The  F-series source use fixed pulse durations and are suitable for conventional fiber-laser marking and engraving. The M-series source provide a wider adjustable pulse-duration and frequency range, allowing the marking process to be adapted more precisely to the material and required surface result.
96 )))
97
98
99
100
101 = UV Laser Models =
102
103 The High-Light UV models use a 355 nm air-cooled UV laser source.
104
105 (% class="table-condensed table-striped" %)
106 |=Specification|=High-Light UV3|=High-Light UV6
107 |Output power|3 W|6 W
108 |Wavelength|355 nm|355 nm
109 |Pulse energy|10 mJ|10 mJ
110 |Beam quality|M² < 1.5|M² < 1.5
111 |Peak power|Up to 10 kW|Up to 10 kW
112 |Pulse frequency|100 - 1000 kHz|100 - 1000 kHz
113 |Pulse duration|1.2 ns|1.2 ns
114 |Cooling|Air|Air
115 |Laser power consumption|70 W|70 W
116
117
118
119 = UV Configuration Data =
120
121 (% class="table-condensed table-striped" %)
122 |=Specification|=Value
123 |Standard marking area|Approximately 570 x 270 mm
124 |Maximum workpiece size|Approximately 881 x 340 x 240 mm
125 |Enclosure dimensions|Approximately 1008 x 700 x 880 mm
126 |Electrical axes|X/Y/Z
127 |Optional axis|Rotation axis
128 |Warranty period|24 months from delivery date
129
130 (% class="box infomessage" %)
131 (((
132 UV lasers are suitable for applications requiring a small heat-affected zone, fine details, and controlled processing of sensitive materials.
133 )))
134
135
136
137
138 = Ultrashort-Pulse Laser =
139
140 The High-Light UKP configuration uses a water-cooled picosecond laser source.
141
142 (% class="table-condensed table-striped" %)
143 |=Specification|=High-Light UKP
144 |Output power|50 W
145 |Pulse energy|25 mJ
146 |Beam quality|M² < 1.4; typical value 1.2
147 |Wavelength|1030 nm
148 |Peak power|25 MW
149 |Pulse frequency|50-2000 kHz
150 |Pulse duration|1-5 ps
151 |Cooling|Water
152 |Laser power consumption|< 300 W
153 |Standard marking area|Approximately 570 x 270 mm
154 |Maximum workpiece size|Approximately 800 x 500 x 300 mm
155 |Enclosure dimensions|Approximately 1040 x 860 x 2025 mm
156 |Electrical axes|X/Y/Z
157 |Optional axis|Rotation axis
158 |Warranty stated in manual|24 months from delivery data
159
160 (% class="box infomessage" %)
161 (((
162 The picosecond source is intended for precision processing where a very short pulse duration and minimal thermal influence are required.
163 )))
164
165
166
167
168 = Operating Conditions =
169
170 (% class="table-condensed table-striped" %)
171 |=Requirement|=Specification
172 |Ambient temperature|+15 ºC to +35 ºC
173 |Relative humidity|Maximum 90%, non-condensing
174 |Cooling aiflow|Ventilation openings and filter mats must remain unobstructed
175 |Extraction|Suitable fume and particle extraction required
176 |Installation position|Upright on a level, clean, and stable floor
177
178 (% class="box infomessage" %)
179 (((
180 Allow the machine to reach room temperature before operation if it has been exposed to substantial temperature changes.
181 )))
182
183
184
185
186 = Dimensions Of High-Light =
187
188 [[image:1788326475149-538.png]]