Version 3.4 von jadomatis am 2026/09/01 13:30

Zeige letzte Bearbeiter
1 **Description**: Learn the technical specifications of High-Light laser marking machine.
2
3 ----
4
5 = Introduction =
6
7 The High-Light is an enclosed industrial laser marking workstation designed for processing large workpieces and extended marking areas. It combines an electrically operated safety enclosure with software-controlled X-, Y-, and Z-axes.
8
9 The system is available with fiber, MOPA fiber, UV and ultrashort-pulse laser sources. The exact technical data depend on the installed laser configuration.
10
11 = Standard Configuration =
12
13 The standard High-Light configuration includes:
14
15 * Schilling laser source
16 * Enclosed Laser Class 1 workstation
17 * Large laser protection window, approximately 750 x 300 mm
18 * Perforated fixture plate
19 * Automatic electric U-shaped lifting door with internal safety monitoring
20 * Fully enclosed wheeled base frame
21 * Integrated pilot laser
22 * Integrated focus laser
23 * Software-controlled X/Y/Z axis system
24 * Z-axis travel of approximately 300 mm
25 * X/Y-axis travel of approximately 460 x 260 mm
26 * Axis motors and control system
27 * Swivel arm with keyboard and monitor holders
28 * AnyMarker Designer marking software
29 * Optional rotation axis
30
31 The supplied equipment and software may vary according to the ordered configuration.
32
33 = General Technical Data =
34
35 (% class="table-condensed table-striped" %)
36 |=Specification|=High-Light
37 |Standard marking area|Approximately 570 x 270 mm
38 |Alternative marking areas|Available on request
39 |Electrical axes|X-, Y, and Z-axis
40 |Optional axis|Rotation axis
41 |X/Y travel|Approximately 460 x 260 mm
42 |Z-axis travel|Approximately 300 mm
43 |Safety classification|Laser Class 1 with intact protective enclosure
44 |Door|Automatic electric U-shaped lifting door
45 |Door monitoring|Internal safety interlock
46 |Positioning system|Pilot laser
47 |Focusing aid|Focus laser
48 |Standard software|AnyMarker Designer
49 |Power connection|230 V
50 |Network connection|Ethernet
51 |External interface|I/O interface
52 |Extraction connection|Integrated connection point
53 |Warranty period|24 months from delivery date
54
55 (% class="box infomessage" %)
56 (((
57 The laser source inside the machine can generate Class 4 laser radiation. The complete workstation operates as Laser Class 1 only while all protective panels, doors, interlocks, seals, and laser protection windows are intact and functioning properly.
58 )))
59
60 = Fiber And MOPA Fiber Laser Models =
61
62 The fiber-laser configurations use air-cooled laser source with a fiber length of 3 m.
63
64 (% class="table-condensed table-striped" %)
65 |=Model|=Output power|=Pulse energy|=Beam quality|=(% style="width: 33px;" %)Pulse frequency|=(% style="width: 35px;" %)Pulse duration|=Laser power consumption
66 |High-Light F20|20 W| | |(% style="width:33px" %) |(% style="width:35px" %) |
67 |High-Light F30| | | |(% style="width:33px" %) |(% style="width:35px" %) |
68 |High-Light F50| | | |(% style="width:33px" %) |(% style="width:35px" %) |
69 |High-Light M20| | | |(% style="width:33px" %) |(% style="width:35px" %) |
70 |High-Light M30| | | |(% style="width:33px" %) |(% style="width:35px" %) |
71 |High-Light M100| | | |(% style="width:33px" %) |(% style="width:35px" %) |
72 |High-Light M200| | | |(% style="width:33px" %) |(% style="width:35px" %) |
73 |High-Light M250| | | |(% style="width:33px" %) |(% style="width:35px" %) |
74
75