Changes for page High-Light Technical Specifications
Last modified by jadomatis on 2026/09/02 07:32
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,5 +1,7 @@ 1 1 **Description**: Learn the technical specifications of High-Light laser marking machine. 2 2 3 +{{toc/}} 4 + 3 3 ---- 4 4 5 5 = Introduction = ... ... @@ -88,9 +88,13 @@ 88 88 |Optional axis|Rotation axis 89 89 |Positioning and focus lasers|Included 90 90 93 +(% class="box infomessage" %) 94 +((( 91 91 TheĀ F-series source use fixed pulse durations and are suitable for conventional fiber-laser marking and engraving. The M-series source provide a wider adjustable pulse-duration and frequency range, allowing the marking process to be adapted more precisely to the material and required surface result. 96 +))) 92 92 93 93 99 + 94 94 = UV Laser Models = 95 95 96 96 The High-Light UV models use a 355 nm air-cooled UV laser source. ... ... @@ -120,9 +120,13 @@ 120 120 |Optional axis|Rotation axis 121 121 |Warranty period|24 months from delivery date 122 122 129 +(% class="box infomessage" %) 130 +((( 123 123 UV lasers are suitable for applications requiring a small heat-affected zone, fine details, and controlled processing of sensitive materials. 132 +))) 124 124 125 125 135 + 126 126 = Ultrashort-Pulse Laser = 127 127 128 128 The High-Light UKP configuration uses a water-cooled picosecond laser source. ... ... @@ -145,9 +145,13 @@ 145 145 |Optional axis|Rotation axis 146 146 |Warranty stated in manual|24 months from delivery data 147 147 158 +(% class="box infomessage" %) 159 +((( 148 148 The picosecond source is intended for precision processing where a very short pulse duration and minimal thermal influence are required. 161 +))) 149 149 150 150 164 + 151 151 = Operating Conditions = 152 152 153 153 (% class="table-condensed table-striped" %) ... ... @@ -158,7 +158,13 @@ 158 158 |Extraction|Suitable fume and particle extraction required 159 159 |Installation position|Upright on a level, clean, and stable floor 160 160 175 +(% class="box infomessage" %) 176 +((( 161 161 Allow the machine to reach room temperature before operation if it has been exposed to substantial temperature changes. 178 +))) 162 162 163 163 164 -= = 181 + 182 += Dimensions Of High-Light = 183 + 184 +[[image:1788326475149-538.png]]
- 1788326475149-538.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.jadomatis - Size
-
... ... @@ -1,0 +1,1 @@ 1 +112.8 KB - Content