Changes for page High-Light Technical Specifications
Last modified by jadomatis on 2026/09/02 07:32
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -High-Light Technical Specifications WIP1 +High-Light Technical Specifications - Content
-
... ... @@ -10,66 +10,4 @@ 10 10 11 11 = Standard Configuration = 12 12 13 -The standard High-Light configuration includes: 14 - 15 -* Schilling laser source 16 -* Enclosed Laser Class 1 workstation 17 -* Large laser protection window, approximately 750 x 300 mm 18 -* Perforated fixture plate 19 -* Automatic electric U-shaped lifting door with internal safety monitoring 20 -* Fully enclosed wheeled base frame 21 -* Integrated pilot laser 22 -* Integrated focus laser 23 -* Software-controlled X/Y/Z axis system 24 -* Z-axis travel of approximately 300 mm 25 -* X/Y-axis travel of approximately 460 x 260 mm 26 -* Axis motors and control system 27 -* Swivel arm with keyboard and monitor holders 28 -* AnyMarker Designer marking software 29 -* Optional rotation axis 30 - 31 -The supplied equipment and software may vary according to the ordered configuration. 32 - 33 -= General Technical Data = 34 - 35 -(% class="table-condensed table-striped" %) 36 -|=Specification|=High-Light 37 -|Standard marking area|Approximately 570 x 270 mm 38 -|Alternative marking areas|Available on request 39 -|Electrical axes|X-, Y, and Z-axis 40 -|Optional axis|Rotation axis 41 -|X/Y travel|Approximately 460 x 260 mm 42 -|Z-axis travel|Approximately 300 mm 43 -|Safety classification|Laser Class 1 with intact protective enclosure 44 -|Door|Automatic electric U-shaped lifting door 45 -|Door monitoring|Internal safety interlock 46 -|Positioning system|Pilot laser 47 -|Focusing aid|Focus laser 48 -|Standard software|AnyMarker Designer 49 -|Power connection|230 V 50 -|Network connection|Ethernet 51 -|External interface|I/O interface 52 -|Extraction connection|Integrated connection point 53 -|Warranty period|24 months from delivery date 54 - 55 -(% class="box infomessage" %) 56 -((( 57 -The laser source inside the machine can generate Class 4 laser radiation. The complete workstation operates as Laser Class 1 only while all protective panels, doors, interlocks, seals, and laser protection windows are intact and functioning properly. 58 -))) 59 - 60 -= Fiber And MOPA Fiber Laser Models = 61 - 62 -The fiber-laser configurations use air-cooled laser source with a fiber length of 3 m. 63 - 64 -(% class="table-condensed table-striped" %) 65 -|=Model|=Output power|=Pulse energy|=(% style="width: 132px;" %)Beam quality|=(% style="width: 117px;" %)Pulse frequency|=(% style="width: 35px;" %)Pulse duration|=Laser power consumption 66 -|High-Light F20|20 W|Approx. 1 mJ|(% style="width:132px" %)M² < 1.5|(% style="width:117px" %)30-60kHz|(% style="width:35px" %) | 67 -|High-Light F30|30 W|Approx. 1 mJ|(% style="width:132px" %)M² < 1.5|(% style="width:117px" %)20-60kHz|(% style="width:35px" %) | 68 -|High-Light F50|50 W|Approx. 1 mJ|(% style="width:132px" %)M² < 1.8|(% style="width:117px" %)50-100kHz|(% style="width:35px" %) | 69 -|High-Light M20|20 W|Approx. 0.7 mJ|(% style="width:132px" %)M² < 1.3|(% style="width:117px" %)1-2000kHz|(% style="width:35px" %) | 70 -|High-Light M30|30 W|Approx. 1 mJ|(% style="width:132px" %)M² < 1.3|(% style="width:117px" %)1-2000kHz|(% style="width:35px" %) | 71 -|High-Light M100|100 W|Approx. 1.5 mJ|(% style="width:132px" %)M² < 1.6|(% style="width:117px" %)1-2000kHz|(% style="width:35px" %) | 72 -|High-Light M200|200 W|Approx. 1.5 mJ|(% style="width:132px" %)M² < 1.6|(% style="width:117px" %)1-2000kHz|(% style="width:35px" %) | 73 -|High-Light M250|250 W|Approx. 1.5 mJ|(% style="width:132px" %)M² < 1.8|(% style="width:117px" %)20 - 60kHz|(% style="width:35px" %) | 74 - 75 - 13 +The standard High-Light configurat