Änderungen von Dokument High-Light Technical Specifications
Zuletzt geändert von jadomatis am 2026/09/02 07:32
Zusammenfassung
-
Seiteneigenschaften (1 geändert, 0 hinzugefügt, 0 gelöscht)
Details
- Seiteneigenschaften
-
- Inhalt
-
... ... @@ -127,38 +127,4 @@ 127 127 128 128 The High-Light UKP configuration uses a water-cooled picosecond laser source. 129 129 130 -(% class="table-condensed table-striped" %) 131 -|=Specification|=High-Light UKP 132 -|Output power|50 W 133 -|Pulse energy|25 mJ 134 -|Beam quality|M² < 1.4; typical value 1.2 135 -|Wavelength|1030 nm 136 -|Peak power|25 MW 137 -|Pulse frequency|50-2000 kHz 138 -|Pulse duration|1-5 ps 139 -|Cooling|Water 140 -|Laser power consumption|< 300 W 141 -|Standard marking area|Approximately 570 x 270 mm 142 -|Maximum workpiece size|Approximately 800 x 500 x 300 mm 143 -|Enclosure dimensions|Approximately 1040 x 860 x 2025 mm 144 -|Electrical axes|X/Y/Z 145 -|Optional axis|Rotation axis 146 -|Warranty stated in manual|24 months from delivery data 147 - 148 -The picosecond source is intended for precision processing where a very short pulse duration and minimal thermal influence are required. 149 - 150 - 151 -= Operating Conditions = 152 - 153 -(% class="table-condensed table-striped" %) 154 -|=Requirement|=Specification 155 -|Ambient temperature|+15 ºC to +35 ºC 156 -|Relative humidity|Maximum 90%, non-condensing 157 -|Cooling aiflow|Ventilation openings and filter mats must remain unobstructed 158 -|Extraction|Suitable fume and particle extraction required 159 -|Installation position|Upright on a level, clean, and stable floor 160 - 161 -Allow the machine to reach room temperature before operation if it has been exposed to substantial temperature changes. 162 - 163 - 164 -= = 130 +