... ... @@ -127,40 +127,4 @@
127 127  
128 128  The High-Light UKP configuration uses a water-cooled picosecond laser source.
129 129  
130 -(% class="table-condensed table-striped" %)
131 -|=Specification|=High-Light UKP
132 -|Output power|50 W
133 -|Pulse energy|25 mJ
134 -|Beam quality|M² < 1.4; typical value 1.2
135 -|Wavelength|1030 nm
136 -|Peak power|25 MW
137 -|Pulse frequency|50-2000 kHz
138 -|Pulse duration|1-5 ps
139 -|Cooling|Water
140 -|Laser power consumption|< 300 W
141 -|Standard marking area|Approximately 570 x 270 mm
142 -|Maximum workpiece size|Approximately 800 x 500 x 300 mm
143 -|Enclosure dimensions|Approximately 1040 x 860 x 2025 mm
144 -|Electrical axes|X/Y/Z
145 -|Optional axis|Rotation axis
146 -|Warranty stated in manual|24 months from delivery data
147 -
148 -The picosecond source is intended for precision processing where a very short pulse duration and minimal thermal influence are required.
149 -
150 -
151 -= Operating Conditions =
152 -
153 -(% class="table-condensed table-striped" %)
154 -|=Requirement|=Specification
155 -|Ambient temperature|+15 ºC to +35 ºC
156 -|Relative humidity|Maximum 90%, non-condensing
157 -|Cooling aiflow|Ventilation openings and filter mats must remain unobstructed
158 -|Extraction|Suitable fume and particle extraction required
159 -|Installation position|Upright on a level, clean, and stable floor
160 -
161 -Allow the machine to reach room temperature before operation if it has been exposed to substantial temperature changes.
162 -
163 -
164 -= Dimensional And Configuration Notes =
165 -
166 -The High-Light dimensional drawing shows that additional operating space is required for the swivel mounted monitor and keyboard controls. This clearance must be considered when planning the installation location.
130 +