77 77  = Fiber And MOPA Configuration Data =
78 -
79 -(% class="table-striped" %)
80 -|=Specification|=Value
81 -|Wavelength|Approximately 1060-1070 nm
82 -|Cooling|Air
83 -|Fiber length|3 m
84 -|Standard marking area|Approximately 570 x 270 mm
85 -|Maximum workpiece size|Approximately 800 x 500 x 300 mm
86 -|Enclosure dimensions|Approximately 1040 x 860 x 2025 mm
87 -|Electrical axes|X/Y/Z
88 -|Optional axis|Rotation axis
89 -|Positioning and focus lasers|Included
90 -
91 -The  F-series source use fixed pulse durations and are suitable for conventional fiber-laser marking and engraving. The M-series source provide a wider adjustable pulse-duration and frequency range, allowing the marking process to be adapted more precisely to the material and required surface result.
92 -
93 -
94 -= UV Laser Models =
95 -
96 -The High-Light UV models use a 355 nm air-cooled UV laser source.
97 -
98 -(% class="table-condensed table-striped" %)
99 -|=Specification|=High-Light UV3|=High-Light UV6
100 -|Output power|3 W|6 W
101 -|Wavelength|355 nm|355 nm
102 -|Pulse energy|10 mJ|10 mJ
103 -|Beam quality|M² < 1.5|M² < 1.5
104 -|Peak power|Up to 10 kW|Up to 10 kW
105 -|Pulse frequency|100 - 1000 kHz|100 - 1000 kHz
106 -|Pulse duration|1.2 ns|1.2 ns
107 -|Cooling|Air|Air
108 -|Laser power consumption|70 W|70 W
109 -
110 -
111 -
112 -= UV Configuration Data =
113 -
114 -(% class="table-condensed table-striped" %)
115 -|=Specification|=Value
116 -|Standard marking area|Approximately 570 x 270 mm
117 -|Maximum workpiece size|Approximately 881 x 340 x 240 mm
118 -|Enclosure dimensions|Approximately 1008 x 700 x 880 mm
119 -|Electrical axes|X/Y/Z
120 -|Optional axis|Rotation axis
121 -|Warranty period|24 months from delivery date
122 -
123 -UV lasers are suitable for applications requiring a small heat-affected zone, fine details, and controlled processing of sensitive materials.
124 -
125 -
126 -= Ultrashort-Pulse Laser =
127 -
128 -The High-Light UKP configuration uses a water-cooled picosecond laser source.
129 -
130 -(% class="table-condensed table-striped" %)
131 -|=Specification|=High-Light UKP
132 -|Output power|50 W
133 -|Pulse energy|25 mJ
134 -|Beam quality|M² < 1.4; typical value 1.2
135 -|Wavelength|1030 nm
136 -|Peak power|25 MW
137 -|Pulse frequency|50-2000 kHz
138 -|Pulse duration|1-5 ps
139 -|Cooling|Water
140 -|Laser power consumption|< 300 W
141 -|Standard marking area|Approximately 570 x 270 mm
142 -|Maximum workpiece size|Approximately 800 x 500 x 300 mm
143 -|Enclosure dimensions|Approximately 1040 x 860 x 2025 mm
144 -|Electrical axes|X/Y/Z
145 -|Optional axis|Rotation axis
146 -|Warranty stated in manual|24 months from delivery data
147 -
148 -The picosecond source is intended for precision processing where a very short pulse duration and minimal thermal influence are required.
149 -
150 -
151 -= Operating Conditions =
152 -
153 -(% class="table-condensed table-striped" %)
154 -|=Requirement|=Specification
155 -|Ambient temperature|+15 ºC to +35 ºC
156 -|Relative humidity|Maximum 90%, non-condensing
157 -|Cooling aiflow|Ventilation openings and filter mats must remain unobstructed
158 -|Extraction|Suitable fume and particle extraction required
159 -|Installation position|Upright on a level, clean, and stable floor
160 -
161 -Allow the machine to reach room temperature before operation if it has been exposed to substantial temperature changes.
162 -
163 -
164 -= Dimensional And Configuration Notes =
165 -
166 -The High-Light dimensional drawing shows that additional operating space is required for the swivel mounted monitor and keyboard controls. This clearance must be considered when planning the installation location.