1 1  **Description**: Learn the technical specifications of High-Light laser marking machine.
2 2  
3 +{{toc/}}
4 +
3 3  ----
4 4  
5 5  = Introduction =
... ... @@ -88,9 +88,13 @@
88 88  |Optional axis|Rotation axis
89 89  |Positioning and focus lasers|Included
90 90  
93 +(% class="box infomessage" %)
94 +(((
91 91  The  F-series source use fixed pulse durations and are suitable for conventional fiber-laser marking and engraving. The M-series source provide a wider adjustable pulse-duration and frequency range, allowing the marking process to be adapted more precisely to the material and required surface result.
96 +)))
92 92  
93 93  
99 +
94 94  = UV Laser Models =
95 95  
96 96  The High-Light UV models use a 355 nm air-cooled UV laser source.
... ... @@ -120,9 +120,13 @@
120 120  |Optional axis|Rotation axis
121 121  |Warranty period|24 months from delivery date
122 122  
129 +(% class="box infomessage" %)
130 +(((
123 123  UV lasers are suitable for applications requiring a small heat-affected zone, fine details, and controlled processing of sensitive materials.
132 +)))
124 124  
125 125  
135 +
126 126  = Ultrashort-Pulse Laser =
127 127  
128 128  The High-Light UKP configuration uses a water-cooled picosecond laser source.
... ... @@ -145,17 +145,30 @@
145 145  |Optional axis|Rotation axis
146 146  |Warranty stated in manual|24 months from delivery data
147 147  
158 +(% class="box infomessage" %)
159 +(((
148 148  The picosecond source is intended for precision processing where a very short pulse duration and minimal thermal influence are required.
161 +)))
149 149  
150 150  
164 +
151 151  = Operating Conditions =
152 152  
153 153  (% class="table-condensed table-striped" %)
154 154  |=Requirement|=Specification
155 -|Ambient temperature|
156 -|Relative humidity|
157 -|Cooling |
158 -| |
159 -| |
169 +|Ambient temperature|+15 ºC to +35 ºC
170 +|Relative humidity|Maximum 90%, non-condensing
171 +|Cooling aiflow|Ventilation openings and filter mats must remain unobstructed
172 +|Extraction|Suitable fume and particle extraction required
173 +|Installation position|Upright on a level, clean, and stable floor
160 160  
161 -
175 +(% class="box infomessage" %)
176 +(((
177 +Allow the machine to reach room temperature before operation if it has been exposed to substantial temperature changes.
178 +)))
179 +
180 +
181 +
182 += Dimensions Of High-Light =
183 +
184 +[[image:1788326475149-538.png]]