Änderungen von Dokument High-Light Technical Specifications
Zuletzt geändert von jadomatis am 2026/09/02 07:32
Zusammenfassung
-
Seiteneigenschaften (1 geändert, 0 hinzugefügt, 0 gelöscht)
Details
- Seiteneigenschaften
-
- Inhalt
-
... ... @@ -140,9 +140,27 @@ 140 140 |Laser power consumption|< 300 W 141 141 |Standard marking area|Approximately 570 x 270 mm 142 142 |Maximum workpiece size|Approximately 800 x 500 x 300 mm 143 -|Enclosure dimensions|Approximately 1040 x 144 -|Electrical axes| 145 -|Optional axis| 146 -|Warranty stated in manual| 143 +|Enclosure dimensions|Approximately 1040 x 860 x 2025 mm 144 +|Electrical axes|X/Y/Z 145 +|Optional axis|Rotation axis 146 +|Warranty stated in manual|24 months from delivery data 147 147 148 - 148 +The picosecond source is intended for precision processing where a very short pulse duration and minimal thermal influence are required. 149 + 150 + 151 += Operating Conditions = 152 + 153 +(% class="table-condensed table-striped" %) 154 +|=Requirement|=Specification 155 +|Ambient temperature|+15 ºC to +35 ºC 156 +|Relative humidity|Maximum 90%, non-condensing 157 +|Cooling aiflow|Ventilation openings and filter mats must remain unobstructed 158 +|Extraction|Suitable fume and particle extraction required 159 +|Installation position|Upright on a level, clean, and stable floor 160 + 161 +Allow the machine to reach room temperature before operation if it has been exposed to substantial temperature changes. 162 + 163 + 164 += Dimensional And Configuration Notes = 165 + 166 +The High-Light dimensional drawing shows that additional operating space is required for the swivel mounted monitor and keyboard controls. This clearance must be considered when planning the installation location.