... ... @@ -129,20 +129,36 @@
129 129  
130 130  (% class="table-condensed table-striped" %)
131 131  |=Specification|=High-Light UKP
132 -|Output power|
133 -|Pulse energy|
134 -|Beam quality|
135 -|Wavelength|
136 -|Peak power|
137 -|Pulse frequency|
138 -|Pulse duration|
139 -|Cooling|
140 -|Laser power consumption|
141 -|Standard marking area|
142 -|Maximum workpiece size|
143 -|Enclosure dimensions|
144 -|Electrical axes|
145 -|Optional axis|
146 -|Warranty stated in manual|
132 +|Output power|50 W
133 +|Pulse energy|25 mJ
134 +|Beam quality|M² < 1.4; typical value 1.2
135 +|Wavelength|1030 nm
136 +|Peak power|25 MW
137 +|Pulse frequency|50-2000 kHz
138 +|Pulse duration|1-5 ps
139 +|Cooling|Water
140 +|Laser power consumption|< 300 W
141 +|Standard marking area|Approximately 570 x 270 mm
142 +|Maximum workpiece size|Approximately 800 x 500 x 300 mm
143 +|Enclosure dimensions|Approximately 1040 x 860 x 2025 mm
144 +|Electrical axes|X/Y/Z
145 +|Optional axis|Rotation axis
146 +|Warranty stated in manual|24 months from delivery data
147 147  
148 -
148 +The picosecond source is intended for precision processing where a very short pulse duration and minimal thermal influence are required.
149 +
150 +
151 += Operating Conditions =
152 +
153 +(% class="table-condensed table-striped" %)
154 +|=Requirement|=Specification
155 +|Ambient temperature|+15 ºC to +35 ºC
156 +|Relative humidity|Maximum 90%, non-condensing
157 +|Cooling aiflow|Ventilation openings and filter mats must remain unobstructed
158 +|Extraction|Suitable fume and particle extraction required
159 +|Installation position|Upright on a level, clean, and stable floor
160 +
161 +Allow the machine to reach room temperature before operation if it has been exposed to substantial temperature changes.
162 +