Changes for page High-Light Technical Specifications
Last modified by jadomatis on 2026/09/02 07:32
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -99,7 +99,7 @@ 99 99 |=Specification|=High-Light UV3|=High-Light UV6 100 100 |Output power|3 W|6 W 101 101 |Wavelength|355 nm|355 nm 102 -|Pulse energy|10 *|10*102 +|Pulse energy|10 mJ|10 mJ 103 103 |Beam quality|M² < 1.5|M² < 1.5 104 104 |Peak power|Up to 10 kW|Up to 10 kW 105 105 |Pulse frequency|100 - 1000 kHz|100 - 1000 kHz ... ... @@ -111,4 +111,56 @@ 111 111 112 112 = UV Configuration Data = 113 113 114 - 114 +(% class="table-condensed table-striped" %) 115 +|=Specification|=Value 116 +|Standard marking area|Approximately 570 x 270 mm 117 +|Maximum workpiece size|Approximately 881 x 340 x 240 mm 118 +|Enclosure dimensions|Approximately 1008 x 700 x 880 mm 119 +|Electrical axes|X/Y/Z 120 +|Optional axis|Rotation axis 121 +|Warranty period|24 months from delivery date 122 + 123 +UV lasers are suitable for applications requiring a small heat-affected zone, fine details, and controlled processing of sensitive materials. 124 + 125 + 126 += Ultrashort-Pulse Laser = 127 + 128 +The High-Light UKP configuration uses a water-cooled picosecond laser source. 129 + 130 +(% class="table-condensed table-striped" %) 131 +|=Specification|=High-Light UKP 132 +|Output power|50 W 133 +|Pulse energy|25 mJ 134 +|Beam quality|M² < 1.4; typical value 1.2 135 +|Wavelength|1030 nm 136 +|Peak power|25 MW 137 +|Pulse frequency|50-2000 kHz 138 +|Pulse duration|1-5 ps 139 +|Cooling|Water 140 +|Laser power consumption|< 300 W 141 +|Standard marking area|Approximately 570 x 270 mm 142 +|Maximum workpiece size|Approximately 800 x 500 x 300 mm 143 +|Enclosure dimensions|Approximately 1040 x 860 x 2025 mm 144 +|Electrical axes|X/Y/Z 145 +|Optional axis|Rotation axis 146 +|Warranty stated in manual|24 months from delivery data 147 + 148 +The picosecond source is intended for precision processing where a very short pulse duration and minimal thermal influence are required. 149 + 150 + 151 += Operating Conditions = 152 + 153 +(% class="table-condensed table-striped" %) 154 +|=Requirement|=Specification 155 +|Ambient temperature|+15 ºC to +35 ºC 156 +|Relative humidity|Maximum 90%, non-condensing 157 +|Cooling aiflow|Ventilation openings and filter mats must remain unobstructed 158 +|Extraction|Suitable fume and particle extraction required 159 +|Installation position|Upright on a level, clean, and stable floor 160 + 161 +Allow the machine to reach room temperature before operation if it has been exposed to substantial temperature changes. 162 + 163 + 164 += Dimensions Of High-Light = 165 + 166 +[[image:1788326475149-538.png]]
- 1788326403448-554.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.jadomatis - Size
-
... ... @@ -1,0 +1,1 @@ 1 +89.2 KB - Content
- 1788326475149-538.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.jadomatis - Size
-
... ... @@ -1,0 +1,1 @@ 1 +112.8 KB - Content