... ... @@ -99,7 +99,7 @@
99 99  |=Specification|=High-Light UV3|=High-Light UV6
100 100  |Output power|3 W|6 W
101 101  |Wavelength|355 nm|355 nm
102 -|Pulse energy|10*|10*
102 +|Pulse energy|10 mJ|10 mJ
103 103  |Beam quality|M² < 1.5|M² < 1.5
104 104  |Peak power|Up to 10 kW|Up to 10 kW
105 105  |Pulse frequency|100 - 1000 kHz|100 - 1000 kHz
... ... @@ -111,4 +111,56 @@
111 111  
112 112  = UV Configuration Data =
113 113  
114 -
114 +(% class="table-condensed table-striped" %)
115 +|=Specification|=Value
116 +|Standard marking area|Approximately 570 x 270 mm
117 +|Maximum workpiece size|Approximately 881 x 340 x 240 mm
118 +|Enclosure dimensions|Approximately 1008 x 700 x 880 mm
119 +|Electrical axes|X/Y/Z
120 +|Optional axis|Rotation axis
121 +|Warranty period|24 months from delivery date
122 +
123 +UV lasers are suitable for applications requiring a small heat-affected zone, fine details, and controlled processing of sensitive materials.
124 +
125 +
126 += Ultrashort-Pulse Laser =
127 +
128 +The High-Light UKP configuration uses a water-cooled picosecond laser source.
129 +
130 +(% class="table-condensed table-striped" %)
131 +|=Specification|=High-Light UKP
132 +|Output power|50 W
133 +|Pulse energy|25 mJ
134 +|Beam quality|M² < 1.4; typical value 1.2
135 +|Wavelength|1030 nm
136 +|Peak power|25 MW
137 +|Pulse frequency|50-2000 kHz
138 +|Pulse duration|1-5 ps
139 +|Cooling|Water
140 +|Laser power consumption|< 300 W
141 +|Standard marking area|Approximately 570 x 270 mm
142 +|Maximum workpiece size|Approximately 800 x 500 x 300 mm
143 +|Enclosure dimensions|Approximately 1040 x 860 x 2025 mm
144 +|Electrical axes|X/Y/Z
145 +|Optional axis|Rotation axis
146 +|Warranty stated in manual|24 months from delivery data
147 +
148 +The picosecond source is intended for precision processing where a very short pulse duration and minimal thermal influence are required.
149 +
150 +
151 += Operating Conditions =
152 +
153 +(% class="table-condensed table-striped" %)
154 +|=Requirement|=Specification
155 +|Ambient temperature|+15 ºC to +35 ºC
156 +|Relative humidity|Maximum 90%, non-condensing
157 +|Cooling aiflow|Ventilation openings and filter mats must remain unobstructed
158 +|Extraction|Suitable fume and particle extraction required
159 +|Installation position|Upright on a level, clean, and stable floor
160 +
161 +Allow the machine to reach room temperature before operation if it has been exposed to substantial temperature changes.
162 +
163 +
164 += Dimensional And Configuration Notes =