Last modified by jadomatis on 2026/09/02 07:32

From version 4.11
edited by jadomatis
on 2026/09/02 05:54
Change comment: There is no comment for this version
To version 4.21
edited by jadomatis
on 2026/09/02 06:53
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -75,3 +75,74 @@
75 75  
76 76  
77 77  = Fiber And MOPA Configuration Data =
78 +
79 +(% class="table-striped" %)
80 +|=Specification|=Value
81 +|Wavelength|Approximately 1060-1070 nm
82 +|Cooling|Air
83 +|Fiber length|3 m
84 +|Standard marking area|Approximately 570 x 270 mm
85 +|Maximum workpiece size|Approximately 800 x 500 x 300 mm
86 +|Enclosure dimensions|Approximately 1040 x 860 x 2025 mm
87 +|Electrical axes|X/Y/Z
88 +|Optional axis|Rotation axis
89 +|Positioning and focus lasers|Included
90 +
91 +The  F-series source use fixed pulse durations and are suitable for conventional fiber-laser marking and engraving. The M-series source provide a wider adjustable pulse-duration and frequency range, allowing the marking process to be adapted more precisely to the material and required surface result.
92 +
93 +
94 += UV Laser Models =
95 +
96 +The High-Light UV models use a 355 nm air-cooled UV laser source.
97 +
98 +(% class="table-condensed table-striped" %)
99 +|=Specification|=High-Light UV3|=High-Light UV6
100 +|Output power|3 W|6 W
101 +|Wavelength|355 nm|355 nm
102 +|Pulse energy|10 mJ|10 mJ
103 +|Beam quality|M² < 1.5|M² < 1.5
104 +|Peak power|Up to 10 kW|Up to 10 kW
105 +|Pulse frequency|100 - 1000 kHz|100 - 1000 kHz
106 +|Pulse duration|1.2 ns|1.2 ns
107 +|Cooling|Air|Air
108 +|Laser power consumption|70 W|70 W
109 +
110 +
111 +
112 += UV Configuration Data =
113 +
114 +(% class="table-condensed table-striped" %)
115 +|=Specification|=Value
116 +|Standard marking area|Approximately 570 x 270 mm
117 +|Maximum workpiece size|Approximately 881 x 340 x 240 mm
118 +|Enclosure dimensions|Approximately 1008 x 700 x 880 mm
119 +|Electrical axes|X/Y/Z
120 +|Optional axis|Rotation axis
121 +|Warranty period|24 months from delivery date
122 +
123 +UV lasers are suitable for applications requiring a small heat-affected zone, fine details, and controlled processing of sensitive materials.
124 +
125 +
126 += Ultrashort-Pulse Laser =
127 +
128 +The High-Light UKP configuration uses a water-cooled picosecond laser source.
129 +
130 +(% class="table-condensed table-striped" %)
131 +|=Specification|=High-Light UKP
132 +| |
133 +| |
134 +| |
135 +| |
136 +| |
137 +| |
138 +| |
139 +| |
140 +| |
141 +| |
142 +| |
143 +| |
144 +| |
145 +| |
146 +| |
147 +
148 +