Änderungen von Dokument High-Light Technical Specifications

Zuletzt geändert von jadomatis am 2026/09/02 07:32

Von Version 1.8
bearbeitet von jadomatis
am 2026/09/01 12:50
Änderungskommentar: Es gibt keinen Kommentar für diese Version
Auf Version 4.1
bearbeitet von jadomatis
am 2026/09/01 13:31
Änderungskommentar: Es gibt keinen Kommentar für diese Version

Zusammenfassung

Details

Seiteneigenschaften
Titel
... ... @@ -1,1 +1,1 @@
1 -High-Light Technical Specifications
1 +High-Light Technical Specifications WIP
Inhalt
... ... @@ -34,22 +34,42 @@
34 34  
35 35  (% class="table-condensed table-striped" %)
36 36  |=Specification|=High-Light
37 -|Standard marking area|
38 -|Alternative marking areas|
39 -|Electrical axes|
40 -|Optional axis|
41 -|X/Y travel|
42 -|Safety classification|
43 -|Door|
44 -|Door monitoring|
45 -|Positioning system|
46 -|Focusing aid|
47 -| |
48 -| |
49 -| |
50 -| |
51 -| |
52 -| |
53 -| |
37 +|Standard marking area|Approximately 570 x 270 mm
38 +|Alternative marking areas|Available on request
39 +|Electrical axes|X-, Y, and Z-axis
40 +|Optional axis|Rotation axis
41 +|X/Y travel|Approximately 460 x 260 mm
42 +|Z-axis travel|Approximately 300 mm
43 +|Safety classification|Laser Class 1 with intact protective enclosure
44 +|Door|Automatic electric U-shaped lifting door
45 +|Door monitoring|Internal safety interlock
46 +|Positioning system|Pilot laser
47 +|Focusing aid|Focus laser
48 +|Standard software|AnyMarker Designer
49 +|Power connection|230 V
50 +|Network connection|Ethernet
51 +|External interface|I/O interface
52 +|Extraction connection|Integrated connection point
53 +|Warranty period|24 months from delivery date
54 54  
55 +(% class="box infomessage" %)
56 +(((
57 +The laser source inside the machine can generate Class 4 laser radiation. The complete workstation operates as Laser Class 1 only while all protective panels, doors, interlocks, seals, and laser protection windows are intact and functioning properly.
58 +)))
59 +
60 += Fiber And MOPA Fiber Laser Models =
61 +
62 +The fiber-laser configurations use air-cooled laser source with a fiber length of 3 m.
63 +
64 +(% class="table-condensed table-striped" %)
65 +|=Model|=Output power|=Pulse energy|=Beam quality|=(% style="width: 33px;" %)Pulse frequency|=(% style="width: 35px;" %)Pulse duration|=Laser power consumption
66 +|High-Light F20|20 W| | |(% style="width:33px" %) |(% style="width:35px" %) |
67 +|High-Light F30| | | |(% style="width:33px" %) |(% style="width:35px" %) |
68 +|High-Light F50| | | |(% style="width:33px" %) |(% style="width:35px" %) |
69 +|High-Light M20| | | |(% style="width:33px" %) |(% style="width:35px" %) |
70 +|High-Light M30| | | |(% style="width:33px" %) |(% style="width:35px" %) |
71 +|High-Light M100| | | |(% style="width:33px" %) |(% style="width:35px" %) |
72 +|High-Light M200| | | |(% style="width:33px" %) |(% style="width:35px" %) |
73 +|High-Light M250| | | |(% style="width:33px" %) |(% style="width:35px" %) |
74 +
55 55