Last modified by jadomatis on 2026/09/02 07:32

From version 1.7
edited by jadomatis
on 2026/09/01 12:49
Change comment: There is no comment for this version
To version 4.9
edited by jadomatis
on 2026/09/02 05:52
Change comment: There is no comment for this version

Summary

Details

Page properties
Title
... ... @@ -1,1 +1,1 @@
1 -High-Light Technical Specifications
1 +High-Light Technical Specifications WIP
Content
... ... @@ -34,22 +34,42 @@
34 34  
35 35  (% class="table-condensed table-striped" %)
36 36  |=Specification|=High-Light
37 -|Standard marking area|
38 -|Alternative marking areas|
39 -|Electrical axes|
40 -|Optional axis|
41 -|X/Y travel|
42 -|Safety classification|
43 -| |
44 -| |
45 -| |
46 -| |
47 -| |
48 -| |
49 -| |
50 -| |
51 -| |
52 -| |
53 -| |
37 +|Standard marking area|Approximately 570 x 270 mm
38 +|Alternative marking areas|Available on request
39 +|Electrical axes|X-, Y, and Z-axis
40 +|Optional axis|Rotation axis
41 +|X/Y travel|Approximately 460 x 260 mm
42 +|Z-axis travel|Approximately 300 mm
43 +|Safety classification|Laser Class 1 with intact protective enclosure
44 +|Door|Automatic electric U-shaped lifting door
45 +|Door monitoring|Internal safety interlock
46 +|Positioning system|Pilot laser
47 +|Focusing aid|Focus laser
48 +|Standard software|AnyMarker Designer
49 +|Power connection|230 V
50 +|Network connection|Ethernet
51 +|External interface|I/O interface
52 +|Extraction connection|Integrated connection point
53 +|Warranty period|24 months from delivery date
54 54  
55 +(% class="box infomessage" %)
56 +(((
57 +The laser source inside the machine can generate Class 4 laser radiation. The complete workstation operates as Laser Class 1 only while all protective panels, doors, interlocks, seals, and laser protection windows are intact and functioning properly.
58 +)))
59 +
60 += Fiber And MOPA Fiber Laser Models =
61 +
62 +The fiber-laser configurations use air-cooled laser source with a fiber length of 3 m.
63 +
64 +(% class="table-condensed table-striped" %)
65 +|=Model|=Output power|=Pulse energy|=(% style="width: 132px;" %)Beam quality|=(% style="width: 117px;" %)Pulse frequency|=(% style="width: 174px;" %)Pulse duration|=(% style="width: 218px;" %)Laser power consumption
66 +|High-Light F20|20 W|Approx. 1 mJ|(% style="width:132px" %)M² < 1.5|(% style="width:117px" %)30-60kHz|(% style="width:174px" %)100 ns|(% style="width:218px" %)< 200 W
67 +|High-Light F30|30 W|Approx. 1 mJ|(% style="width:132px" %)M² < 1.5|(% style="width:117px" %)20-60kHz|(% style="width:174px" %)100 ns|(% style="width:218px" %)< 300 W
68 +|High-Light F50|50 W|Approx. 1 mJ|(% style="width:132px" %)M² < 1.8|(% style="width:117px" %)50-100kHz|(% style="width:174px" %)100 ns|(% style="width:218px" %)< 340 W
69 +|High-Light M20|20 W|Approx. 0.7 mJ|(% style="width:132px" %)M² < 1.3|(% style="width:117px" %)1-2000kHz|(% style="width:174px" %)2-550 ns|(% style="width:218px" %)< 150 W
70 +|High-Light M30|30 W|Approx. 1 mJ|(% style="width:132px" %)M² < 1.3|(% style="width:117px" %)1-2000kHz|(% style="width:174px" %)2-550 ns|(% style="width:218px" %)
71 +|High-Light M100|100 W|Approx. 1.5 mJ|(% style="width:132px" %)M² < 1.6|(% style="width:117px" %)1-2000kHz|(% style="width:174px" %)10-350 ns|(% style="width:218px" %)
72 +|High-Light M200|200 W|Approx. 1.5 mJ|(% style="width:132px" %)M² < 1.6|(% style="width:117px" %)1-4000kHz|(% style="width:174px" %)10-350 ns|(% style="width:218px" %)
73 +|High-Light M250|250 W|Approx. 1.5 mJ|(% style="width:132px" %)M² < 1.8|(% style="width:117px" %)1-4000kHz|(% style="width:174px" %)10-350 ns|(% style="width:218px" %)
74 +
55 55