Änderungen von Dokument High-Light Technical Specifications

Zuletzt geändert von jadomatis am 2026/09/02 07:32

Von Version 1.10
bearbeitet von jadomatis
am 2026/09/01 13:15
Änderungskommentar: Es gibt keinen Kommentar für diese Version
Auf Version 4.2
bearbeitet von jadomatis
am 2026/09/02 05:43
Änderungskommentar: Es gibt keinen Kommentar für diese Version

Zusammenfassung

Details

Seiteneigenschaften
Titel
... ... @@ -1,1 +1,1 @@
1 -High-Light Technical Specifications
1 +High-Light Technical Specifications WIP
Inhalt
... ... @@ -34,22 +34,42 @@
34 34  
35 35  (% class="table-condensed table-striped" %)
36 36  |=Specification|=High-Light
37 -|Standard marking area|Approximately
38 -|Alternative marking areas|
39 -|Electrical axes|
40 -|Optional axis|
41 -|X/Y travel|
42 -|Z-axis travel|
43 -|Safety classification|
44 -|Door|
45 -|Door monitoring|
46 -|Positioning system|
47 -|Focusing aid|
48 -|Standard software|
49 -|Power connection|
50 -|Network connection|
51 -|External interface|
52 -|Extraction connection|
53 -|Warranty period|
37 +|Standard marking area|Approximately 570 x 270 mm
38 +|Alternative marking areas|Available on request
39 +|Electrical axes|X-, Y, and Z-axis
40 +|Optional axis|Rotation axis
41 +|X/Y travel|Approximately 460 x 260 mm
42 +|Z-axis travel|Approximately 300 mm
43 +|Safety classification|Laser Class 1 with intact protective enclosure
44 +|Door|Automatic electric U-shaped lifting door
45 +|Door monitoring|Internal safety interlock
46 +|Positioning system|Pilot laser
47 +|Focusing aid|Focus laser
48 +|Standard software|AnyMarker Designer
49 +|Power connection|230 V
50 +|Network connection|Ethernet
51 +|External interface|I/O interface
52 +|Extraction connection|Integrated connection point
53 +|Warranty period|24 months from delivery date
54 54  
55 +(% class="box infomessage" %)
56 +(((
57 +The laser source inside the machine can generate Class 4 laser radiation. The complete workstation operates as Laser Class 1 only while all protective panels, doors, interlocks, seals, and laser protection windows are intact and functioning properly.
58 +)))
59 +
60 += Fiber And MOPA Fiber Laser Models =
61 +
62 +The fiber-laser configurations use air-cooled laser source with a fiber length of 3 m.
63 +
64 +(% class="table-condensed table-striped" %)
65 +|=Model|=Output power|=Pulse energy|=Beam quality|=(% style="width: 33px;" %)Pulse frequency|=(% style="width: 35px;" %)Pulse duration|=Laser power consumption
66 +|High-Light F20|20 W| | |(% style="width:33px" %) |(% style="width:35px" %) |
67 +|High-Light F30|30 W| | |(% style="width:33px" %) |(% style="width:35px" %) |
68 +|High-Light F50|50 W| | |(% style="width:33px" %) |(% style="width:35px" %) |
69 +|High-Light M20|20 W| | |(% style="width:33px" %) |(% style="width:35px" %) |
70 +|High-Light M30|30 W| | |(% style="width:33px" %) |(% style="width:35px" %) |
71 +|High-Light M100|100 W| | |(% style="width:33px" %) |(% style="width:35px" %) |
72 +|High-Light M200|200 W| | |(% style="width:33px" %) |(% style="width:35px" %) |
73 +|High-Light M250|250 W| | |(% style="width:33px" %) |(% style="width:35px" %) |
74 +
55 55