Wiki source code of Operation (Start, Run, Shutdown)
Hide last authors
| author | version | line-number | content |
|---|---|---|---|
| |
1.2 | 1 | **Description: **Learn the normal operating sequence for the High-Light laser marking system, including switching on the system, preparing and running a marking job, and shutting down the system. |
| 2 | |||
| 3 | ---- | ||
| 4 | |||
| 5 | (% class="box warningmessage" %) | ||
| 6 | ((( | ||
| |
1.3 | 7 | Only trained and authorized personnel may operate the High-Light. Observe all applicable laser safety instructions before using the system. |
| |
1.2 | 8 | ))) |
| |
1.3 | 9 | |
| |
1.4 | 10 | = Before You Start = |
| 11 | |||
| 12 | Before switching on the High-Light: | ||
| 13 | |||
| 14 | * Check the system for visible damage, | ||
| |
1.5 | 15 | * Make sure the protective housing, lifting door, safety switches and laser protection window are undamaged. |
| 16 | * Make sure all covers and protective panels are installed correctly. | ||
| 17 | * Check that the Emergency Stop button is released. | ||
| 18 | * Make sure the system has acclimatized to room temperature if it exposed to significant temperature changes, | ||
| 19 | * Check that the ventilation openings and filter mats are unobstructed. | ||
| 20 | * Make sure the extraction system is connected and ready for operation. | ||
| |
1.6 | 21 | * Check that the optical components are clean. |
| 22 | * Remove the protective cover from the laser focusing lens. | ||
| 23 | * Make sure the work area is clear of unnecessary objects. | ||
| 24 | |||
| |
1.7 | 25 | Do not operate the system if the protective housing, lifting door, safety switches, sealing profiles, or laser protection window are damaged. |
| 26 | |||
| 27 | |||
| 28 | = Switch On = | ||
| 29 | |||
| |
1.8 | 30 | 1. Make sure the cabin door is open. |
| 31 | 1. Connect the control PC or laptop to the laser system. | ||
| 32 | 1. Switch on the laser system. | ||
| 33 | 1. If the blue Acknowledge button is illuminated, press it once. | ||
| |
1.9 | 34 | 1. Start the marking software configured for the system - Never start laser marking software before turning on the laser system. |
| 35 | 1. Wait for the software to connect to the laser automatically. | ||
| 36 | 1. Confirm that the green system-ready LED is illuminated continuously. | ||
| 37 | 1. Confirm that the two red positioned-laser points are visible. | ||
| 38 | |||
| 39 | The High-Light is now ready for job preparation. | ||
| 40 | |||
| 41 | |||
| |
1.22 | 42 | = Prepare The Marking Job = |
| |
1.9 | 43 | |
| |
1.10 | 44 | 1. Perform the reference run required by the installed axis configuration. |
| |
1.11 | 45 | The standard High-Light configuration includes software-controlled X,Y and Z axes. Complete all reference movements requested by the control software before positioning the workpiece. |
| |
1.12 | 46 | 1. Create a new marking file or open an approved existing file. |
| 47 | 1. Load the validated marking parameters for the workpiece material and required marking result. | ||
| 48 | 1. Set the Z-axis to the required focal height. | ||
| |
1.13 | 49 | 1. Secure the workpiece in the appropriate fixture. |
| 50 | 1. Use the pilot laser to display the marking area or marking contours. | ||
| |
1.14 | 51 | 1. Check that the marking is correctly positioned on the workpiece. |
| 52 | 1. Where the marking program uses X- and Y-axis movement, verify that the programmed axis positions and travel area are suitable for the installed fixture and workpiece. | ||
| 53 | |||
| 54 | Do not start the marking process until the workpiece is securely positioned and the marking location has been verified. | ||
| 55 | |||
| 56 | |||
| |
1.22 | 57 | = Run The Marking = |
| |
1.14 | 58 | |
| |
1.15 | 59 | 1. Switch on the extraction system. |
| 60 | 1. Close the cabin door completely. | ||
| 61 | 1. Confirm that the yellow LED is illuminated. This indicated that the door safely circuit is satisfied. | ||
| |
1.16 | 62 | 1. Check the marking software for active warnings or fault messages. |
| 63 | 1. Start the marking process. | ||
| 64 | 1. During the marking, the red laser-active LED should be illuminated. | ||
| 65 | 1. The programmed marking sequence runs automatically. | ||
| |
1.17 | 66 | 1. Monitor the system during operation. Do not leave High-Light unattended. |
| 67 | 1. When the marking process is complete, the red LED switches off while the yellow LED remains illuminated. | ||
| |
1.18 | 68 | 1. Open the lifting door using the normal machine controls and remove the marked workpiece. |
| 69 | |||
| 70 | (% class="box warningmessage" %) | ||
| 71 | ((( | ||
| 72 | Never open the cabin or attempt to access the work are while the red laser-active LED is illuminated. | ||
| 73 | ))) | ||
| 74 | |||
| 75 | |||
| 76 | |||
| |
1.22 | 77 | = Check The Marking Results = |
| |
1.19 | 78 | |
| 79 | Inspect the completed marking for: | ||
| 80 | |||
| 81 | * Correct position | ||
| 82 | * Legibility | ||
| 83 | * Contrast | ||
| 84 | * Completeness | ||
| |
1.20 | 85 | * Required marking depth or surface effect |
| 86 | |||
| 87 | If the result is unsatisfactory, check the focal height, workpiece position, marking parameters, and selected marking file before repeating the process. | ||
| 88 | |||
| |
1.21 | 89 | Do not change validated production parameters without authorization. |
| 90 | |||
| 91 | |||
| 92 | = Shutdown = | ||
| 93 | |||
| 94 | 1. Allow the current marking process to finish or stop it safely through the marking software. | ||
| 95 | 1. Save the marking file and any required production data. | ||
| 96 | 1. Close the marking software on the control PC. | ||
| 97 | 1. Switch off the laser system using the main switch. | ||
| 98 | 1. Switch off the extraction system after any remaining fumes or particles have been removed from the cabin. | ||
| 99 | 1. Remove finished workpieces and unnecessary materials from the work area. | ||
| 100 | 1. Leave the cabin and surrounding work area clean. | ||
| 101 | |||
| 102 | |||
| 103 | |||
| |
1.22 | 104 | = If The System Is Not Ready = |
| 105 | |||
| 106 | * Green LED remains off: | ||
| 107 | * Blue button remains illuminated: |