8 )))
9
10 = Before You Start =
11
12 Before switching on the High-Light:
13
14 * Check the system for visible damage,
15 * Make sure the protective housing, lifting door, safety switches and laser protection window are undamaged.
16 * Make sure all covers and protective panels are installed correctly.
17 * Check that the Emergency Stop button is released.
18 * Make sure the system has acclimatized to room temperature if it exposed to significant temperature changes,
19 * Check that the ventilation openings and filter mats are unobstructed.
20 * Make sure the extraction system is connected and ready for operation.
21 * Check that the optical components are clean.
22 * Remove the protective cover from the laser focusing lens.
23 * Make sure the work area is clear of unnecessary objects.
24
25 Do not operate the system if the protective housing, lifting door, safety switches, sealing profiles, or laser protection window are damaged.
26
27
28 = Switch On =
29
30 1. Make sure the cabin door is open.
31 1. Connect the control PC or laptop to the laser system.
32 1. Switch on the laser system.
33 1. If the blue Acknowledge button is illuminated, press it once.
34 1. Start the marking software configured for the system - Never start laser marking software before turning on the laser system.
35 1. Wait for the software to connect to the laser automatically.
36 1. Confirm that the green system-ready LED is illuminated continuously.
37 1. Confirm that the two red positioned-laser points are visible.
38
39 The High-Light is now ready for job preparation.
40
41
42 = Prepare the Marking Job =
43
44 1. Perform the reference run required by the installed axis configuration.
45 The standard High-Light configuration includes software-controlled X,Y and Z axes. Complete all reference movements requested by the control software before positioning the workpiece.
46 1. Create a new marking file or open an approved existing file.
47 1. Load the validated marking parameters for the workpiece material and required marking result.
48 1. Set the Z-axis to the required focal height.
49 1. Secure the workpiece in the appropriate fixture.
50 1. Use the pilot laser to display the marking area or marking contours.
51 1. Check that the marking is correctly positioned on the workpiece.
52 1. Where the marking program uses X- and Y-axis movement, verify that the programmed axis positions and travel area are suitable for the installed fixture and workpiece.
53
54 Do not start the marking process until the workpiece is securely positioned and the marking location has been verified.
55
56
57 = Run the Marking =
58
59 1. Switch on the extraction system.
60 1. Close the cabin door completely.
61 1. Confirm that the yellow LED is illuminated. This indicated that the door safely circuit is satisfied.
62 1. Check the marking software for active warnings or fault messages.
63 1. Start the marking process.
64 1. During the marking, the red laser-active LED should be illuminated.
65 1. The programmed marking sequence runs automatically.
66 1. Monitor the system during operation. Do not leave High-Light unattended.
67 1. When the marking process is complete, the red LED switches off while the yellow LED remains illuminated.
68 1. Open the lifting door using the normal machine controls and remove the marked workpiece.
69
70 (% class="box warningmessage" %)
71 (((
72 Never open the cabin or attempt to access the work are while the red laser-active LED is illuminated.
73 )))
74
75
76
77 = Check the Marking Results =
78
79 Inspect the completed marking for:
80
81 * Correct position
82 * Legibility
83 * Contrast
84 * Completeness
85 * Required marking depth or surface effect
86
87 If the result is unsatisfactory, check the focal height, workpiece position, marking parameters, and selected marking file before repeating the process.
88
89 Do not change validated production parameters without authorization.
90
91
92 = Shutdown =
93
94 1. Allow the current marking process to finish or stop it safely through the marking software.
95 1. Save the marking file and any required production data.
96 1. Close the marking software on the control PC.
97 1. Switch off the laser system using the main switch.
98 1. Switch off the extraction system after any remaining fumes or particles have been removed from the cabin.
99 1. Remove finished workpieces and unnecessary materials from the work area.