Last modified by jadomatis on 2026/09/01 08:14

From version 3.1
edited by jadomatis
on 2026/09/01 08:14
Change comment: There is no comment for this version
To version 1.20
edited by jadomatis
on 2026/09/01 08:01
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,7 +1,5 @@
1 1  **Description: **Learn the normal operating sequence for the High-Light laser marking system, including switching on the system, preparing and running a marking job, and shutting down the system.
2 2  
3 -{{toc/}}
4 -
5 5  ----
6 6  
7 7  (% class="box warningmessage" %)
... ... @@ -9,7 +9,6 @@
9 9  Only trained and authorized personnel may operate the High-Light. Observe all applicable laser safety instructions before using the system.
10 10  )))
11 11  
12 -
13 13  = Before You Start =
14 14  
15 15  Before switching on the High-Light:
... ... @@ -42,7 +42,7 @@
42 42  The High-Light is now ready for job preparation.
43 43  
44 44  
45 -= Prepare The Marking Job =
42 += Prepare the Marking Job =
46 46  
47 47  1. Perform the reference run required by the installed axis configuration.
48 48  The standard High-Light configuration includes software-controlled X,Y and Z axes. Complete all reference movements requested by the control software before positioning the workpiece.
... ... @@ -57,7 +57,7 @@
57 57  Do not start the marking process until the workpiece is securely positioned and the marking location has been verified.
58 58  
59 59  
60 -= Run The Marking =
57 += Run the Marking =
61 61  
62 62  1. Switch on the extraction system.
63 63  1. Close the cabin door completely.
... ... @@ -77,7 +77,7 @@
77 77  
78 78  
79 79  
80 -= Check The Marking Results =
77 += Check the Marking Results =
81 81  
82 82  Inspect the completed marking for:
83 83  
... ... @@ -89,28 +89,4 @@
89 89  
90 90  If the result is unsatisfactory, check the focal height, workpiece position, marking parameters, and selected marking file before repeating the process.
91 91  
92 -Do not change validated production parameters without authorization.
93 -
94 -
95 -= Shutdown =
96 -
97 -1. Allow the current marking process to finish or stop it safely through the marking software.
98 -1. Save the marking file and any required production data.
99 -1. Close the marking software on the control PC.
100 -1. Switch off the laser system using the main switch.
101 -1. Switch off the extraction system after any remaining fumes or particles have been removed from the cabin.
102 -1. Remove finished workpieces and unnecessary materials from the work area.
103 -1. Leave the cabin and surrounding work area clean.
104 -
105 -
106 -
107 -= If The System Is Not Ready =
108 -
109 -* **Green LED remains off**: The system may be waiting for acknowledgement. Press the blue Acknowledge button.
110 -* **Blue button remains illuminated**: Check that the Emergency Stop button is released.
111 -* **Yellow LED remains off**: Check that the cabin door is completely closed
112 -* **Red LED does not illuminate when marking is started**: Check the Emergency Stop, cabin door, safety circuit, and software messages.
113 -* **Marking is weak or not visible**: Check the Z-axis position and focal height, then verify the marking parameters.
114 -* **Axis movement is unavailable**: Complete the required reference run and clear any active fault messages.
115 -
116 -If a fault cannot be corrected safely, switch off the system and contact Schilling Marking Systems or authorized personnel.
89 +Do not change validated