Last modified by jadomatis on 2026/09/01 08:14

From version 3.1
edited by jadomatis
on 2026/09/01 08:14
Change comment: There is no comment for this version
To version 1.13
edited by jadomatis
on 2026/09/01 07:50
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,7 +1,5 @@
1 1  **Description: **Learn the normal operating sequence for the High-Light laser marking system, including switching on the system, preparing and running a marking job, and shutting down the system.
2 2  
3 -{{toc/}}
4 -
5 5  ----
6 6  
7 7  (% class="box warningmessage" %)
... ... @@ -9,7 +9,6 @@
9 9  Only trained and authorized personnel may operate the High-Light. Observe all applicable laser safety instructions before using the system.
10 10  )))
11 11  
12 -
13 13  = Before You Start =
14 14  
15 15  Before switching on the High-Light:
... ... @@ -42,7 +42,7 @@
42 42  The High-Light is now ready for job preparation.
43 43  
44 44  
45 -= Prepare The Marking Job =
42 += Prepare the Marking Job =
46 46  
47 47  1. Perform the reference run required by the installed axis configuration.
48 48  The standard High-Light configuration includes software-controlled X,Y and Z axes. Complete all reference movements requested by the control software before positioning the workpiece.
... ... @@ -51,66 +51,4 @@
51 51  1. Set the Z-axis to the required focal height.
52 52  1. Secure the workpiece in the appropriate fixture.
53 53  1. Use the pilot laser to display the marking area or marking contours.
54 -1. Check that the marking is correctly positioned on the workpiece.
55 -1. Where the marking program uses X- and Y-axis movement, verify that the programmed axis positions and travel area are suitable for the installed fixture and workpiece.
56 -
57 -Do not start the marking process until the workpiece is securely positioned and the marking location has been verified.
58 -
59 -
60 -= Run The Marking =
61 -
62 -1. Switch on the extraction system.
63 -1. Close the cabin door completely.
64 -1. Confirm that the yellow LED is illuminated. This indicated that the door safely circuit is satisfied.
65 -1. Check the marking software for active warnings or fault messages.
66 -1. Start the marking process.
67 -1. During the marking, the red laser-active LED should be illuminated.
68 -1. The programmed marking sequence runs automatically.
69 -1. Monitor the system during operation. Do not leave High-Light unattended.
70 -1. When the marking process is complete, the red LED switches off while the yellow LED remains illuminated.
71 -1. Open the lifting door using the normal machine controls and remove the marked workpiece.
72 -
73 -(% class="box warningmessage" %)
74 -(((
75 -Never open the cabin or attempt to access the work are while the red laser-active LED is illuminated.
76 -)))
77 -
78 -
79 -
80 -= Check The Marking Results =
81 -
82 -Inspect the completed marking for:
83 -
84 -* Correct position
85 -* Legibility
86 -* Contrast
87 -* Completeness
88 -* Required marking depth or surface effect
89 -
90 -If the result is unsatisfactory, check the focal height, workpiece position, marking parameters, and selected marking file before repeating the process.
91 -
92 -Do not change validated production parameters without authorization.
93 -
94 -
95 -= Shutdown =
96 -
97 -1. Allow the current marking process to finish or stop it safely through the marking software.
98 -1. Save the marking file and any required production data.
99 -1. Close the marking software on the control PC.
100 -1. Switch off the laser system using the main switch.
101 -1. Switch off the extraction system after any remaining fumes or particles have been removed from the cabin.
102 -1. Remove finished workpieces and unnecessary materials from the work area.
103 -1. Leave the cabin and surrounding work area clean.
104 -
105 -
106 -
107 -= If The System Is Not Ready =
108 -
109 -* **Green LED remains off**: The system may be waiting for acknowledgement. Press the blue Acknowledge button.
110 -* **Blue button remains illuminated**: Check that the Emergency Stop button is released.
111 -* **Yellow LED remains off**: Check that the cabin door is completely closed
112 -* **Red LED does not illuminate when marking is started**: Check the Emergency Stop, cabin door, safety circuit, and software messages.
113 -* **Marking is weak or not visible**: Check the Z-axis position and focal height, then verify the marking parameters.
114 -* **Axis movement is unavailable**: Complete the required reference run and clear any active fault messages.
115 -
116 -If a fault cannot be corrected safely, switch off the system and contact Schilling Marking Systems or authorized personnel.
51 +1. Check that the marking is correctly posi