... ... @@ -1,5 +1,7 @@
1 1  **Description: **Learn the normal operating sequence for the High-Light laser marking system, including switching on the system, preparing and running a marking job, and shutting down the system.
2 2  
3 +{{toc/}}
4 +
3 3  ----
4 4  
5 5  (% class="box warningmessage" %)
... ... @@ -7,6 +7,7 @@
7 7  Only trained and authorized personnel may operate the High-Light. Observe all applicable laser safety instructions before using the system.
8 8  )))
9 9  
12 +
10 10  = Before You Start =
11 11  
12 12  Before switching on the High-Light:
... ... @@ -27,4 +27,87 @@
27 27  
28 28  = Switch On =
29 29  
30 -1.
33 +1. Make sure the cabin door is open.
34 +1. Connect the control PC or laptop to the laser system.
35 +1. Switch on the laser system.
36 +1. If the blue Acknowledge button is illuminated, press it once.
37 +1. Start the marking software configured for the system - Never start laser marking software before turning on the laser system.
38 +1. Wait for the software to connect to the laser automatically.
39 +1. Confirm that the green system-ready LED is illuminated continuously.
40 +1. Confirm that the two red positioned-laser points are visible.
41 +
42 +The High-Light is now ready for job preparation.
43 +
44 +
45 += Prepare The Marking Job =
46 +
47 +1. Perform the reference run required by the installed axis configuration.
48 +The standard High-Light configuration includes software-controlled X,Y and Z axes. Complete all reference movements requested by the control software before positioning the workpiece.
49 +1. Create a new marking file or open an approved existing file.
50 +1. Load the validated marking parameters for the workpiece material and required marking result.
51 +1. Set the Z-axis to the required focal height.
52 +1. Secure the workpiece in the appropriate fixture.
53 +1. Use the pilot laser to display the marking area or marking contours.
54 +1. Check that the marking is correctly positioned on the workpiece.
55 +1. Where the marking program uses X- and Y-axis movement, verify that the programmed axis positions and travel area are suitable for the installed fixture and workpiece.
56 +
57 +Do not start the marking process until the workpiece is securely positioned and the marking location has been verified.
58 +
59 +
60 += Run The Marking =
61 +
62 +1. Switch on the extraction system.
63 +1. Close the cabin door completely.
64 +1. Confirm that the yellow LED is illuminated. This indicated that the door safely circuit is satisfied.
65 +1. Check the marking software for active warnings or fault messages.
66 +1. Start the marking process.
67 +1. During the marking, the red laser-active LED should be illuminated.
68 +1. The programmed marking sequence runs automatically.
69 +1. Monitor the system during operation. Do not leave High-Light unattended.
70 +1. When the marking process is complete, the red LED switches off while the yellow LED remains illuminated.
71 +1. Open the lifting door using the normal machine controls and remove the marked workpiece.
72 +
73 +(% class="box warningmessage" %)
74 +(((
75 +Never open the cabin or attempt to access the work are while the red laser-active LED is illuminated.
76 +)))
77 +
78 +
79 +
80 += Check The Marking Results =
81 +
82 +Inspect the completed marking for:
83 +
84 +* Correct position
85 +* Legibility
86 +* Contrast
87 +* Completeness
88 +* Required marking depth or surface effect
89 +
90 +If the result is unsatisfactory, check the focal height, workpiece position, marking parameters, and selected marking file before repeating the process.
91 +
92 +Do not change validated production parameters without authorization.
93 +
94 +
95 += Shutdown =
96 +
97 +1. Allow the current marking process to finish or stop it safely through the marking software.
98 +1. Save the marking file and any required production data.
99 +1. Close the marking software on the control PC.
100 +1. Switch off the laser system using the main switch.
101 +1. Switch off the extraction system after any remaining fumes or particles have been removed from the cabin.
102 +1. Remove finished workpieces and unnecessary materials from the work area.
103 +1. Leave the cabin and surrounding work area clean.
104 +
105 +
106 +
107 += If The System Is Not Ready =
108 +
109 +* **Green LED remains off**: The system may be waiting for acknowledgement. Press the blue Acknowledge button.
110 +* **Blue button remains illuminated**: Check that the Emergency Stop button is released.
111 +* **Yellow LED remains off**: Check that the cabin door is completely closed
112 +* **Red LED does not illuminate when marking is started**: Check the Emergency Stop, cabin door, safety circuit, and software messages.
113 +* **Marking is weak or not visible**: Check the Z-axis position and focal height, then verify the marking parameters.
114 +* **Axis movement is unavailable**: Complete the required reference run and clear any active fault messages.
115 +
116 +If a fault cannot be corrected safely, switch off the system and contact Schilling Marking Systems or authorized personnel.