Last modified by jadomatis on 2026/09/01 08:14

From version 1.4
edited by jadomatis
on 2026/09/01 07:03
Change comment: There is no comment for this version
To version 1.7
edited by jadomatis
on 2026/09/01 07:10
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -12,4 +12,19 @@
12 12  Before switching on the High-Light:
13 13  
14 14  * Check the system for visible damage,
15 -* Make sure the protective housing, lift
15 +* Make sure the protective housing, lifting door, safety switches and laser protection window are undamaged.
16 +* Make sure all covers and protective panels are installed correctly.
17 +* Check that the Emergency Stop button is released.
18 +* Make sure the system has acclimatized to room temperature if it exposed to significant temperature changes,
19 +* Check that the ventilation openings and filter mats are unobstructed.
20 +* Make sure the extraction system is connected and ready for operation.
21 +* Check that the optical components are clean.
22 +* Remove the protective cover from the laser focusing lens.
23 +* Make sure the work area is clear of unnecessary objects.
24 +
25 +Do not operate the system if the protective housing, lifting door, safety switches, sealing profiles, or laser protection window are damaged.
26 +
27 +
28 += Switch On =
29 +
30 +1.