Summary

Details

Page properties
Content
... ... @@ -1,5 +1,7 @@
1 1  **Description: **Learn the normal operating sequence for the High-Light laser marking system, including switching on the system, preparing and running a marking job, and shutting down the system.
2 2  
3 +{{toc/}}
4 +
3 3  ----
4 4  
5 5  (% class="box warningmessage" %)
... ... @@ -7,6 +7,7 @@
7 7  Only trained and authorized personnel may operate the High-Light. Observe all applicable laser safety instructions before using the system.
8 8  )))
9 9  
12 +
10 10  = Before You Start =
11 11  
12 12  Before switching on the High-Light:
... ... @@ -103,5 +103,11 @@
103 103  
104 104  = If The System Is Not Ready =
105 105  
106 -* Green LED remains off:
107 -* Blue button remains illuminated:
109 +* **Green LED remains off**: The system may be waiting for acknowledgement. Press the blue Acknowledge button.
110 +* **Blue button remains illuminated**: Check that the Emergency Stop button is released.
111 +* **Yellow LED remains off**: Check that the cabin door is completely closed
112 +* **Red LED does not illuminate when marking is started**: Check the Emergency Stop, cabin door, safety circuit, and software messages.
113 +* **Marking is weak or not visible**: Check the Z-axis position and focal height, then verify the marking parameters.
114 +* **Axis movement is unavailable**: Complete the required reference run and clear any active fault messages.
115 +
116 +If a fault cannot be corrected safely, switch off the system and contact Schilling Marking Systems or authorized personnel.