Changes for page Operation (Start, Run, Shutdown)
Last modified by jadomatis on 2026/09/01 08:14
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -103,5 +103,11 @@ 103 103 104 104 = If The System Is Not Ready = 105 105 106 -* Green LED remains off: 107 -* Blue button remains illuminated: 106 +* **Green LED remains off**: The system may be waiting for acknowledgement. Press the blue Acknowledge button. 107 +* **Blue button remains illuminated**: Check that the Emergency Stop button is released. 108 +* **Yellow LED remains off**: Check that the cabin door is completely closed 109 +* **Red LED does not illuminate when marking is started**: Check the Emergency Stop, cabin door, safety circuit, and software messages. 110 +* **Marking is weak or not visible**: Check the Z-axis position and focal height, then verify the marking parameters. 111 +* **Axis movement is unavailable**: Complete the required reference run and clear any active fault messages. 112 + 113 +If a fault cannot be corrected safely, switch off the system and contact Schilling Marking Systems or authorized personnel.