... ... @@ -39,7 +39,7 @@
39 39  The High-Light is now ready for job preparation.
40 40  
41 41  
42 -= Prepare The Marking Job =
42 += Prepare the Marking Job =
43 43  
44 44  1. Perform the reference run required by the installed axis configuration.
45 45  The standard High-Light configuration includes software-controlled X,Y and Z axes. Complete all reference movements requested by the control software before positioning the workpiece.
... ... @@ -54,7 +54,7 @@
54 54  Do not start the marking process until the workpiece is securely positioned and the marking location has been verified.
55 55  
56 56  
57 -= Run The Marking =
57 += Run the Marking =
58 58  
59 59  1. Switch on the extraction system.
60 60  1. Close the cabin door completely.
... ... @@ -74,7 +74,7 @@
74 74  
75 75  
76 76  
77 -= Check The Marking Results =
77 += Check the Marking Results =
78 78  
79 79  Inspect the completed marking for:
80 80  
... ... @@ -86,22 +86,4 @@
86 86  
87 87  If the result is unsatisfactory, check the focal height, workpiece position, marking parameters, and selected marking file before repeating the process.
88 88  
89 -Do not change validated production parameters without authorization.
90 -
91 -
92 -= Shutdown =
93 -
94 -1. Allow the current marking process to finish or stop it safely through the marking software.
95 -1. Save the marking file and any required production data.
96 -1. Close the marking software on the control PC.
97 -1. Switch off the laser system using the main switch.
98 -1. Switch off the extraction system after any remaining fumes or particles have been removed from the cabin.
99 -1. Remove finished workpieces and unnecessary materials from the work area.
100 -1. Leave the cabin and surrounding work area clean.
101 -
102 -
103 -
104 -= If The System Is Not Ready =
105 -
106 -* Green LED remains off:
107 -* Blue button remains illuminated:
89 +Do not change validated