Last modified by jadomatis on 2026/09/01 08:14

From version 1.21
edited by jadomatis
on 2026/09/01 08:06
Change comment: There is no comment for this version
To version 3.1
edited by jadomatis
on 2026/09/01 08:14
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,5 +1,7 @@
1 1  **Description: **Learn the normal operating sequence for the High-Light laser marking system, including switching on the system, preparing and running a marking job, and shutting down the system.
2 2  
3 +{{toc/}}
4 +
3 3  ----
4 4  
5 5  (% class="box warningmessage" %)
... ... @@ -7,6 +7,7 @@
7 7  Only trained and authorized personnel may operate the High-Light. Observe all applicable laser safety instructions before using the system.
8 8  )))
9 9  
12 +
10 10  = Before You Start =
11 11  
12 12  Before switching on the High-Light:
... ... @@ -39,7 +39,7 @@
39 39  The High-Light is now ready for job preparation.
40 40  
41 41  
42 -= Prepare the Marking Job =
45 += Prepare The Marking Job =
43 43  
44 44  1. Perform the reference run required by the installed axis configuration.
45 45  The standard High-Light configuration includes software-controlled X,Y and Z axes. Complete all reference movements requested by the control software before positioning the workpiece.
... ... @@ -54,7 +54,7 @@
54 54  Do not start the marking process until the workpiece is securely positioned and the marking location has been verified.
55 55  
56 56  
57 -= Run the Marking =
60 += Run The Marking =
58 58  
59 59  1. Switch on the extraction system.
60 60  1. Close the cabin door completely.
... ... @@ -74,7 +74,7 @@
74 74  
75 75  
76 76  
77 -= Check the Marking Results =
80 += Check The Marking Results =
78 78  
79 79  Inspect the completed marking for:
80 80  
... ... @@ -101,4 +101,13 @@
101 101  
102 102  
103 103  
104 -
107 += If The System Is Not Ready =
108 +
109 +* **Green LED remains off**: The system may be waiting for acknowledgement. Press the blue Acknowledge button.
110 +* **Blue button remains illuminated**: Check that the Emergency Stop button is released.
111 +* **Yellow LED remains off**: Check that the cabin door is completely closed
112 +* **Red LED does not illuminate when marking is started**: Check the Emergency Stop, cabin door, safety circuit, and software messages.
113 +* **Marking is weak or not visible**: Check the Z-axis position and focal height, then verify the marking parameters.
114 +* **Axis movement is unavailable**: Complete the required reference run and clear any active fault messages.
115 +
116 +If a fault cannot be corrected safely, switch off the system and contact Schilling Marking Systems or authorized personnel.