... ... @@ -18,72 +18,4 @@
18 18  * Make sure the system has acclimatized to room temperature if it exposed to significant temperature changes,
19 19  * Check that the ventilation openings and filter mats are unobstructed.
20 20  * Make sure the extraction system is connected and ready for operation.
21 -* Check that the optical components are clean.
22 -* Remove the protective cover from the laser focusing lens.
23 -* Make sure the work area is clear of unnecessary objects.
24 -
25 -Do not operate the system if the protective housing, lifting door, safety switches, sealing profiles, or laser protection window are damaged.
26 -
27 -
28 -= Switch On =
29 -
30 -1. Make sure the cabin door is open.
31 -1. Connect the control PC or laptop to the laser system.
32 -1. Switch on the laser system.
33 -1. If the blue Acknowledge button is illuminated, press it once.
34 -1. Start the marking software configured for the system - Never start laser marking software before turning on the laser system.
35 -1. Wait for the software to connect to the laser automatically.
36 -1. Confirm that the green system-ready LED is illuminated continuously.
37 -1. Confirm that the two red positioned-laser points are visible.
38 -
39 -The High-Light is now ready for job preparation.
40 -
41 -
42 -= Prepare the Marking Job =
43 -
44 -1. Perform the reference run required by the installed axis configuration.
45 -The standard High-Light configuration includes software-controlled X,Y and Z axes. Complete all reference movements requested by the control software before positioning the workpiece.
46 -1. Create a new marking file or open an approved existing file.
47 -1. Load the validated marking parameters for the workpiece material and required marking result.
48 -1. Set the Z-axis to the required focal height.
49 -1. Secure the workpiece in the appropriate fixture.
50 -1. Use the pilot laser to display the marking area or marking contours.
51 -1. Check that the marking is correctly positioned on the workpiece.
52 -1. Where the marking program uses X- and Y-axis movement, verify that the programmed axis positions and travel area are suitable for the installed fixture and workpiece.
53 -
54 -Do not start the marking process until the workpiece is securely positioned and the marking location has been verified.
55 -
56 -
57 -= Run the Marking =
58 -
59 -1. Switch on the extraction system.
60 -1. Close the cabin door completely.
61 -1. Confirm that the yellow LED is illuminated. This indicated that the door safely circuit is satisfied.
62 -1. Check the marking software for active warnings or fault messages.
63 -1. Start the marking process.
64 -1. During the marking, the red laser-active LED should be illuminated.
65 -1. The programmed marking sequence runs automatically.
66 -1. Monitor the system during operation. Do not leave High-Light unattended.
67 -1. When the marking process is complete, the red LED switches off while the yellow LED remains illuminated.
68 -1. Open the lifting door using the normal machine controls and remove the marked workpiece.
69 -
70 -(% class="box warningmessage" %)
71 -(((
72 -Never open the cabin or attempt to access the work are while the red laser-active LED is illuminated.
73 -)))
74 -
75 -
76 -
77 -= Check the Marking Results =
78 -
79 -Inspect the completed marking for:
80 -
81 -* Correct position
82 -* Legibility
83 -* Contrast
84 -* Completeness
85 -* Required marking depth or surface effect
86 -
87 -If the result is unsatisfactory, check the focal height, workpiece position, marking parameters, and selected marking file before repeating the process.
88 -
89 -Do not change validated
21 +*