42 42  = Prepare the Marking Job =
43 43  
44 44  1. Perform the reference run required by the installed axis configuration.
45 -The standard High-Light configuration includes software-controlled X,Y and Z axes. Complete all reference movements requested by the control software before positioning the workpiece.
46 -1. Create a new marking file or open an approved existing file.
47 -1. Load the validated marking parameters for the workpiece material and required marking result.
48 -1. Set the Z-axis to the required focal height.
49 -1. Secure the workpiece in the appropriate fixture.
50 -1. Use the pilot laser to display the marking area or marking contours.
51 -1. Check that the marking is correctly positioned on the workpiece.
52 -1. Where the marking program uses X- and Y-axis movement, verify that the programmed axis positions and travel area are suitable for the installed fixture and workpiece.
53 -
54 -Do not start the marking process until the workpiece is securely positioned and the marking location has been verified.
55 -
56 -
57 -= Run the Marking =
58 -
59 -1. Switch on the extraction system.
60 -1. Close the cabin door completely.
61 -1. Confirm that the yellow LED is illuminated. This indicated that the door safely circuit is satisfied.
62 -1. Check the marking software for active warnings or fault messages.
63 -1. Start the marking process.
64 -1. During the marking, the red laser-active LED should be illuminated.
65 -1. The programmed marking sequence runs automatically.
66 -1. Monitor the system during operation. Do not leave High-Light unattended.
67 -1. When the marking process is complete, the red LED switches off while the yellow LED remains illuminated.
68 -1. Open the lifting door u