Changes for page Operation (Start, Run, Shutdown)
Last modified by jadomatis on 2026/09/01 08:14
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -22,28 +22,4 @@ 22 22 * Remove the protective cover from the laser focusing lens. 23 23 * Make sure the work area is clear of unnecessary objects. 24 24 25 -Do not operate the system if the protective housing, lifting door, safety switches, sealing profiles, or laser protection window are damaged. 26 - 27 - 28 -= Switch On = 29 - 30 -1. Make sure the cabin door is open. 31 -1. Connect the control PC or laptop to the laser system. 32 -1. Switch on the laser system. 33 -1. If the blue Acknowledge button is illuminated, press it once. 34 -1. Start the marking software configured for the system - Never start laser marking software before turning on the laser system. 35 -1. Wait for the software to connect to the laser automatically. 36 -1. Confirm that the green system-ready LED is illuminated continuously. 37 -1. Confirm that the two red positioned-laser points are visible. 38 - 39 -The High-Light is now ready for job preparation. 40 - 41 - 42 -= Prepare the Marking Job = 43 - 44 -1. Perform the reference run required by the installed axis configuration. 45 -The standard High-Light configuration includes software-controlled X,Y and Z axes. Complete all reference movements requested by the control software before positioning the workpiece. 46 -1. Create a new marking file or open an approved existing file. 47 -1. Load the validated marking parameters for the workpiece material and required marking result. 48 -1. Set the Z-axis to the required focal height. 49 -1. 25 +Do