Changes for page Operation (Start, Run, Shutdown)
Last modified by jadomatis on 2026/09/01 08:14
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -43,4 +43,23 @@ 43 43 44 44 1. Perform the reference run required by the installed axis configuration. 45 45 The standard High-Light configuration includes software-controlled X,Y and Z axes. Complete all reference movements requested by the control software before positioning the workpiece. 46 -1. Create 46 +1. Create a new marking file or open an approved existing file. 47 +1. Load the validated marking parameters for the workpiece material and required marking result. 48 +1. Set the Z-axis to the required focal height. 49 +1. Secure the workpiece in the appropriate fixture. 50 +1. Use the pilot laser to display the marking area or marking contours. 51 +1. Check that the marking is correctly positioned on the workpiece. 52 +1. Where the marking program uses X- and Y-axis movement, verify that the programmed axis positions and travel area are suitable for the installed fixture and workpiece. 53 + 54 +Do not start the marking process until the workpiece is securely positioned and the marking location has been verified. 55 + 56 + 57 += Run the Marking = 58 + 59 +1. Switch on the extraction system. 60 +1. Close the cabin door completely. 61 +1. Confirm that the yellow LED is illuminated. This indicated that the door safely circuit is satisfied. 62 +1. Check the marking software for active warnings or fault messages. 63 +1. Start the marking process. 64 +1. During the marking, the red laser-active LED should be illuminated. 65 +1. The programmed marking sequence runs automatically.