Summary

Details

Page properties
Content
... ... @@ -1,7 +1,5 @@
1 1  **Description**: Learn how to perform maintenance tasks for your High-Light marking system.
2 2  
3 -{{toc/}}
4 -
5 5  ----
6 6  
7 7  (% class="box warningmessage" %)
... ... @@ -9,116 +9,8 @@
9 9  **Caution:** Before any maintenance work, switch off the power supply and ensure that the High-Light is completely de-energized. All maintenance work must be carried out in accordance with the applicable safety requirements. Do not use flammable or explosive cleaning substances, and do not keep containers with flammable or explosive liquids inside the work chamber.
10 10  )))
11 11  
12 -
13 13  = Responsibilities and Original Parts =
14 14  
15 15  Maintenance should only be performed when the person carrying out the work understands the relevant safety requirements and the procedure involved.
16 16  
17 -Use original replacement parts for worn or damaged machine, safety, and electrical components. The High-Light manual warns that inferior spare parts or third-party components can impair machine safety and invalidate the supplied CE declaration of conformity.
18 -
19 -(% class="box warningmessage" %)
20 -(((
21 -If a fault cannot be corrected safely, switch off the machine and contract service rather continuing operation.
22 -)))
23 -
24 -
25 -= Daily Visual Checks =
26 -
27 -Before beginning normal operation, perform a brief visual inspection of the High-Light.
28 -
29 -**Check**:
30 -
31 -* **Laser lens: **Inspect for contamination and clean if required.
32 -* **Entire work area: **Keep the marking chamber and surrounding working area clean.
33 -* **Laser protection window: **Visually inspect it for damage. If the damage hinders operation, it must be replaced.
34 -* **Optical components: **Check for visible contamination before switching on the system.
35 -
36 -Keeping the working environment clean helps prevent contamination from reaching the sensitive optical components. The manufacturer recommends regular inspection of the filter systems, ventilation and optics to maximize system availability and service life.
37 -
38 -
39 -= Airflow, Filters, and Work Environment =
40 -
41 -The High-Light uses air cooling. Proper airflow therefore must be maintained around the laser and PC components.
42 -
43 -The system contains a filter mat that protects electronic components from dust and contaminants in the surrounding air. It is located behind the ventilation openings at the front of the laser insert or PC. The filter mat should be inspected regularly and replaced when contaminated to maintain an effective cooling condition.
44 -
45 -Suitable extraction is especially important because laser processing can generate gases, vapors, aerosols and dust. These substances can be harmful and may also settle on the working optics, causing reduced laser performance, poor making results or equipment damage.
46 -
47 -
48 -= Cleaning Optical Components =
49 -
50 -Laser optics are highly sensitive and can be damaged more easily than ordinary glass. Preventing contamination through proper extraction and a clean working environment is preferable to frequent cleaning.
51 -
52 -When cleaning optics:
53 -
54 -* Never touch optical surfaces with your fingers.
55 -* Use only soft, lint-free cloth or suitable cleaning paper.
56 -* Use a suitable cleaning solvent.
57 -* For heavier contamination, use lens-cleaning tissues together with alcohol of at least 98% purity.
58 -* Apply the cleaning solution to the cloth rather than dipping the cloth into the solution.
59 -* Do not use tools or hard objects on the optical surfaces.
60 -* Use a small hand-operated air blower to remove loose dust.
61 -* Do not use compressed air, as it may contain small quantities of oil and water.
62 -
63 -When wiping the lens, move gently in light circular motions, beginning in the center and working outward toward the edge. Keep the cloth moving and do not apply pressure to the lens surface.
64 -
65 -
66 -== Objective Protective Glass ==
67 -
68 -The High-Light maintenance schedule separately specifies monthly cleaning of the objective protective glass. For this particular component, the manual instructs the user to clean carefully with a soft cloth moistened with acetone or ethyl ether.
69 -
70 -
71 -= Avoiding Faults - Typical Causes and Remedies =
72 -
73 -Regular maintenance can prevent several common High-Light operating problems.
74 -
75 -
76 -**Weak marking:**
77 -Check the Z-position stored in the job and the current Z-axis position. An incorrect focus height is a common cause of weak marking. Perform a new Z-axis reference run and refocus if necessary. Also verify the marking parameters.
78 -\\**No marking:**
79 -Check that the material is suitable for laser marking, that the cabin door is fully closed, that the yellow status LED is lit up, and that the marking parameters are appropriate.
80 -\\**Marking takes too long:**
81 -Increase speed or power, it can also be the very tight hatching so increase hatch spacing, as well as use an appropriate font to reduce processing time.
82 -\\**Cooling problems or excessive contamination:**
83 -Inspect the ventilation area and filter mat. Keep the working clean and make sure extraction is functioning correctly.
84 -
85 -
86 -= Suggested Maintenance Intervals =
87 -
88 -A recommended maintenance schedule would look like this:
89 -
90 -* **Daily:** 
91 -** Inspect the lens and clean if required
92 -** Clean the entire work area
93 -** Visually inspect the laser protection window for damage.
94 -
95 -* **Monthly:** 
96 -** Clean the objective protective glass
97 -** Clean the laser ventilation area and replace filter mat if heavily contaminated
98 -** Inspect and if necessary clean and reoil the Z-axis spindle
99 -** Inspect protective cabin, laser protection window, sealing profile and laser protection brushes, if fitted
100 -** Inspect pre-filter, if fitted and replace when full
101 -
102 -* **Annually:**
103 -** Inspect extract main filter, if fitted and replace when contaminated
104 -
105 -(% class="box warningmessage" %)
106 -(((
107 -**Important**: Damage to protective cabin, laser protection window sealing profile or laser protection brushes can compromise the machine's **Class 1 laser protection**. If damage is found, notify service immediately and do not continue normal operation until the protective condition has been restored.
108 -)))
109 -
110 -= After Maintenance - Return to Service =
111 -
112 -After maintenance work has been completed:
113 -
114 -1. Make sure all cleaned or serviced components are correctly reinstalled.
115 -1. Verify that the protective cabin, laser protection window, seals and other safety-related components are intact.
116 -1. Remove all cleaning materials, tools and liquids from the work chamber.
117 -1. Confirm that the ventilation and filter system are unobstructed,
118 -1. Check the extraction system and its filters, where installed.
119 -1. Switch the machine on according to the normal High-Light startup procedure.
120 -1. Perform a Z-axis reference run where required.
121 -1. Check focus and positioning before the next production marking.
122 -1. Perform a controlled test marking if maintenance affected the laser source, optics, axes, working field or positioning system.
123 -
124 -Regular inspection and careful cleaning are particularly important for the High-Light because both marking quality and safe operation depends on clean optics, effective cooling, functioning extraction and an intact protective enclosure,
14 +Use original