... ... @@ -70,4 +70,15 @@
70 70  
71 71  The High-Light maintenance schedule separately specifies monthly cleaning of the objective protective glass. For this particular component, the manual instructs the user to clean carefully with a soft cloth moistened with acetone or ethyl ether.
72 72  
73 -
73 +
74 += Avoiding Faults - Typical Causes and Remedies =
75 +
76 +Regular maintenance can prevent several common High-Light operating problems.
77 +
78 +
79 +**Weak marking:**
80 +Check the Z-position stored in the job and the current Z-axis position. An incorrect focus height is a common cause of weak marking. Perform a new Z-axis reference run and refocus if necessary. Also verify the marking parameters.
81 +\\**No marking:**
82 +Check that the material is suitable for laser marking, that the cabin door is fully closed, that the yellow status LED is lit up, and that the marking parameters are appropriate.
83 +\\**Marking takes too long:**