Änderungen von Dokument Maintenance
Zuletzt geändert von jadomatis am 2026/09/01 08:15
Zusammenfassung
-
Seiteneigenschaften (1 geändert, 0 hinzugefügt, 0 gelöscht)
Details
- Seiteneigenschaften
-
- Inhalt
-
... ... @@ -36,4 +36,22 @@ 36 36 37 37 The High-Light uses air cooling. Proper airflow therefore must be maintained around the laser and PC components. 38 38 39 -The system contains a filter mat that protects electr 39 +The system contains a filter mat that protects electronic components from dust and contaminants in the surrounding air. It is located behind the ventilation openings at the front of the laser insert or PC. The filter mat should be inspected regularly and replaced when contaminated to maintain an effective cooling condition. 40 + 41 +A recommended maintenance schedule would look like this: 42 + 43 +* **Monthly**: Clean the laser ventilation area carefully with a dry cloth. 44 +* **As needed**: Replace the filter mat if heavy contamination is present. 45 +* **Monthly**: Inspect the extraction system pre-filter, if an extraction unit is installed. 46 +* **Annually**: Inspect the extraction system main filter and replace it when contaminated. 47 + 48 +Suitable extraction is especially important because laser processing can generate gases, vapors, aerosols and dust. These substances can be harmful and may also settle on the working optics, causing reduced laser performance, poor making results or equipment damage. 49 + 50 + 51 += Cleaning Optical Components = 52 + 53 +Laser optics are highly sensitive and can be damaged more easily than ordinary glass. Preventing contamination through proper extraction and a clean working environment is preferable to frequent cleaning. 54 + 55 +When cleaning optics: 56 + 57 +* Never to