Changes for page Maintenance

Last modified by jadomatis on 2026/09/01 08:15

From version 1.4
edited by jadomatis
on 2026/08/31 10:19
Change comment: There is no comment for this version
To version 1.5
edited by jadomatis
on 2026/08/31 10:28
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -11,4 +11,27 @@
11 11  
12 12  Maintenance should only be performed when the person carrying out the work understands the relevant safety requirements and the procedure involved.
13 13  
14 -Use original
14 +Use original replacement parts for worn or damaged machine, safety, and electrical components. The High-Light manual warns that inferior spare parts or third-party components can impair machine safety and invalidate the supplied CE declaration of conformity.
15 +
16 +(% class="box warningmessage" %)
17 +(((
18 +If a fault cannot be corrected safely, switch off the machine and contract service rather continuing operation.
19 +)))
20 +
21 += Daily Visual Checks =
22 +
23 +Before beginning normal operation, perform a brief visual inspection of the High-Light.
24 +
25 +**Check**:
26 +
27 +* **Laser lens: **Inspect for contamination and clean if required.
28 +* **Entire work area: **Keep the marking chamber and surrounding working area clean.
29 +* **Laser protection window: **Visually inspect it for damage. If the damage hinders operation, it must be replaced.
30 +* **Optical components: **Check for visible contamination before switching on the system.
31 +
32 +Keeping the working environment clean helps prevent contamination from reaching the sensitive optical components. The manufacturer recommends regular inspection of the filter systems, ventilation and optics to maximize system availability and service life.