Changes for page Maintenance

Last modified by jadomatis on 2026/09/01 08:15

From version 1.2
edited by jadomatis
on 2026/08/31 10:14
Change comment: There is no comment for this version
To version 1.10
edited by jadomatis
on 2026/08/31 11:49
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -4,5 +4,66 @@
4 4  
5 5  (% class="box warningmessage" %)
6 6  (((
7 -**Caution:** Before any maintenance work, switch off the power supply and ensure that the High-Light is completely de-energized. All maintenance work must be carried out in
7 +**Caution:** Before any maintenance work, switch off the power supply and ensure that the High-Light is completely de-energized. All maintenance work must be carried out in accordance with the applicable safety requirements. Do not use flammable or explosive cleaning substances, and do not keep containers with flammable or explosive liquids inside the work chamber.
8 8  )))
9 +
10 += Responsibilities and Original Parts =
11 +
12 +Maintenance should only be performed when the person carrying out the work understands the relevant safety requirements and the procedure involved.
13 +
14 +Use original replacement parts for worn or damaged machine, safety, and electrical components. The High-Light manual warns that inferior spare parts or third-party components can impair machine safety and invalidate the supplied CE declaration of conformity.
15 +
16 +(% class="box warningmessage" %)
17 +(((
18 +If a fault cannot be corrected safely, switch off the machine and contract service rather continuing operation.
19 +)))
20 +
21 += Daily Visual Checks =
22 +
23 +Before beginning normal operation, perform a brief visual inspection of the High-Light.
24 +
25 +**Check**:
26 +
27 +* **Laser lens: **Inspect for contamination and clean if required.
28 +* **Entire work area: **Keep the marking chamber and surrounding working area clean.
29 +* **Laser protection window: **Visually inspect it for damage. If the damage hinders operation, it must be replaced.
30 +* **Optical components: **Check for visible contamination before switching on the system.
31 +
32 +Keeping the working environment clean helps prevent contamination from reaching the sensitive optical components. The manufacturer recommends regular inspection of the filter systems, ventilation and optics to maximize system availability and service life.
33 +
34 +
35 += Airflow, Filters, and Work Environment =
36 +
37 +The High-Light uses air cooling. Proper airflow therefore must be maintained around the laser and PC components.
38 +
39 +The system contains a filter mat that protects electronic components from dust and contaminants in the surrounding air. It is located behind the ventilation openings at the front of the laser insert or PC. The filter mat should be inspected regularly and replaced when contaminated to maintain an effective cooling condition.
40 +
41 +A recommended maintenance schedule would look like this:
42 +
43 +* **Monthly**: Clean the laser ventilation area carefully with a dry cloth.
44 +* **As needed**: Replace the filter mat if heavy contamination is present.
45 +* **Monthly**: Inspect the extraction system pre-filter, if an extraction unit is installed.
46 +* **Annually**: Inspect the extraction system main filter and replace it when contaminated.
47 +
48 +Suitable extraction is especially important because laser processing can generate gases, vapors, aerosols and dust. These substances can be harmful and may also settle on the working optics, causing reduced laser performance, poor making results or equipment damage.
49 +
50 +
51 += Cleaning Optical Components =
52 +
53 +Laser optics are highly sensitive and can be damaged more easily than ordinary glass. Preventing contamination through proper extraction and a clean working environment is preferable to frequent cleaning.
54 +
55 +When cleaning optics:
56 +
57 +* Never touch optical surfaces with your fingers.
58 +* Use only soft, lint-free cloth or suitable cleaning paper.
59 +* Use a suitable cleaning solvent.
60 +* For heavier contamination, use lens-cleaning tissues together with alcohol of at least 98% purity.
61 +* Apply the cleaning solution to the cloth rather than dipping the cloth into the solution.
62 +* Do not use tools or hard objects on the optical surfaces.
63 +* Use a small hand-operated air blower to remove loose dust.
64 +* Do not use compressed air, as it may contain small quantities of oil and water.
65 +
66 +When wiping the lens, move gently in light circular motions, beginning in the center and working outward toward the edge. Keep the cloth moving and do not apply pressure to the lens surface.
67 +
68 +
69 +