Commissioning and First Start-Up

Version 2.1 by jadomatis on 2026/08/31 09:14

Description: Learn how to bring the Schilling High-Light laser marking workstation into operation safely after installation or transport.


Only qualified personnel may commission the system. Observe all safety notes before switching on.
Important: Remove the protective cap from the laser objective before starting the laser.

Preconditions(Before Switching On)

Confirm the following before applying power:

  • All packaging material has been removed.
  • All transport locks have been removed.
  • The High-Light is standing upright in its intended operation position.
  • Supply voltage and frequency have been checked against the machine requirements.
  • The mains cable and plug are undamaged.
  • The main switch is in the OFF position before connecting the power cable.
  • The laser protection window is undamaged.
  • Optical components are free from dust and contamination.
  • The protective cover has been removed from the focusing objective.
  • All required laser-safety measures have been implemented and verified.

The operating environments must also meet the High-Light requirements:

  • Ambient temperature: +15 °C to +35 °C.
  • Relative humidity: maximum 90%, non condensing.
  • If the system has experienced significant temperature changes during transport, allow it to return to room temperature before commissioning.
  • Avoid shocks, vibration and other mechanical stress.
  • Keep the ventilation openings and filter areas of both 19" units unobstructed to prevent heat build-up.

Suitable extraction must be available for the marking process. Laser processing can generate gases, vapors, aerosols and dust depending on the material and parameters. The operator is responsible for providing appropriate extraction to protect personnel, the environment and the working optics.

Electrical Start-Up

  1. Verify that the High-Light has been installed correctly and that the main switch is OFF.
  2. Connect the machine to the specified electrical supply.
  3. Ensure that the required extraction system is available and ready for operatoon.
  4. Open the cabin door. 
  5. Connect the control PC/laptop to the laser and switch on the laser system.
  6. If the blue Acknowledge button is illuminated, press it once.
  7. After successful acknowledgement and communication with the controller, the green status LED remains illuminated.

Software and Device Connection

  1. Start AnyMarker Designer on the control PC.
  2. Establish communication with High-Light controller.
  3. Verify that the machine is connected and that no active fault prevents operation.
  4. Confirm that the positioning/focus laser is available. During the startup sequence, two red laser points become visible once the system has initialized successfully.

Initial Checks With Pilot Laser

Before performing the first marking, check that the positioning system is operating correctly.

Create or open a suitable layout in AnyMarker Designer and activate the Pilot function. The positioning laser displays the marking field so that the intended marking location can be checked without using the processing laser.

Verify:

  • The positioning laser is visible.
  • The marking field corresponds to the expected area.
  • The workpiece can be positioned correctly inside the fixture.
  • There are no obstacles within the required movement or marking area.

The final workpiece position should be checked again after focusing and before the protective door is closed.

Z-Axis Focusing

Unlike the Multi-Light commissioning workflow, the High-Light requires a Z-axis reference run before normal operation.

  1. Perform a reference movement of the Z-axis.
  2. Create or open the required marking file.
  3. Move the Z-axis to the required focusing height for the workpiece.
  4. Verify the focus position before marking

Correct focus is essential. The High-Light manual states that incorrect focusing is one of the most common causes of weak or completely invisible markings. The Z-axis should therefore be adjusted until the correct working distance between the marking head and the workpiece surface is achieved.

Parameter Verification

Before the first marking, verify that the selected marking parameters are suitable for the material and the installed laser source.

Relevant parameters documented for High-Light include:

  • Power
  • Frequency
  • Speed
  • Number of passes

Use a verified parameter set whenever one is available.

Parameters must also be selected so that the material is not excessively heated. Inappropriate parameters can create a fire or explosion hazard, particularly when combustible materials or residues are present.

Ensure extraction is operation before performing the actual laser test.

First Test Mark

The High-Light requires a functional check after relocation, the normal marking sequence can be used for a controlled functional check.

  1. Place the sample or workpiece securely in the fixture.
  2. Set the correct Z-axis focus.
  3. Use the positioning laser to verify the marking location
  4. Close the cabin door.
  5. Confirm that the yellow LED illuminates, indicating that the door condition is satisfied.
  6. Start the marking process.
  7. During marking, verify that the red LED is active.
  8. Allow the marking cycle to complete automatically.
  9. At the end of the cycle, the red LED switches off and the yellow LED illuminates again.
  10. Open the cabin door and remove the marked workpiece.

Post-Test Verification

Inspect the first marking before using the High-Light for normal production.

Check:

  • Marking position
  • Readability and contrast
  • Correct focus
  • Correct marking content
  • Overall marking quality

If the marking is too weak, we recommend checking the Z-position in the job, the Z-position in the axis controls, performing a new Z-axis reference run and focusing and verifying the marking parameters.

Also confirm that:

  • No fault messages are present
  • Extraction is functioning correctly.
  • No abnormal contamination has accumulated in the work area or on the optics.
  • The door and safety system operates normally,

Once the result is satisfactory, record or save the verified marking parameters for the production application.

Normal Operation Handover

Before releasing the machine for routine use, operators should be familiar with:

  • Main switch and system startup
  • Acknowledge function
  • Z-axis reference movement
  • Z-axis focusin
  • X/Y/Z positioning
  • Pilot/positioning laser
  • Cabin door and safety interlock
  • Start and stop functions
  • Status LEDs
  • Emergency Stop
  • Extraction requirements

The High-Light includes software-controlled X//Y/Z axes, with approximately 300 mm Z-axis travel and approximately 460 x 260 mm X/Y travel, so operators should understand axis movement and ensure that fixtures and workpieces cannot obstruct the required travel.

Shutdown (End of Day)

  1. Finish the current marking operation.
  2. Save the required marking project or parameters.
  3. Close AnyMarker Designer on the PC.
  4. Switch the High-Light off using the main switch.
  5. Shut down the extraction system according to its operating instructions.
  6. Leave the work chamber and surrounding area clean.

The High-Light is now safely shut down and ready for the next operating cycle.