Changes for page Commissioning and First Start-Up
Last modified by jadomatis on 2026/08/31 10:15
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,7 +1,5 @@ 1 1 **Description**: Learn how to bring the Schilling High-Light laser marking workstation into operation safely after installation or transport. 2 2 3 -{{toc/}} 4 - 5 5 ---- 6 6 7 7 (% class="box warningmessage" %) ... ... @@ -10,7 +10,7 @@ 10 10 Important: Remove the protective cap from the laser objective before starting the laser.** 11 11 ))) 12 12 13 -= Preconditions(Before Switching On) = 11 += Preconditions(Before Switching On) = 14 14 15 15 Confirm the following before applying power: 16 16 ... ... @@ -50,7 +50,7 @@ 50 50 51 51 = Software and Device Connection = 52 52 53 -1. Start** AnyMarker Designer** on the control PC.51 +1. Start** AnyMarker Designer** on the control PC. 54 54 1. Establish communication with High-Light controller. 55 55 1. Verify that the machine is connected and that no active fault prevents operation. 56 56 1. Confirm that the positioning/focus laser is available. During the startup sequence, two red laser points become visible once the system has initialized successfully. ... ... @@ -77,12 +77,12 @@ 77 77 78 78 Unlike the Multi-Light commissioning workflow, the High-Light requires a Z-axis reference run before normal operation. 79 79 80 -1. Perform a** reference movement of the Z-axis**.78 +1. Perform a** reference movement of the Z-axis**. 81 81 1. Create or open the required marking file. 82 82 1. Move the Z-axis to the required focusing height for the workpiece. 83 83 1. Verify the focus position before marking 84 84 85 -Correct focus is essential. Incorrect focusing is one of the most common causes of weak or completely invisible markings. The Z-axis should therefore be adjusted until the correct working distance between the marking head and the workpiece surface is achieved.83 +Correct focus is essential. The High-Light manual states that incorrect focusing is one of the most common causes of weak or completely invisible markings. The Z-axis should therefore be adjusted until the correct working distance between the marking head and the workpiece surface is achieved. 86 86 87 87 88 88 = Parameter Verification = ... ... @@ -137,10 +137,10 @@ 137 137 138 138 (% class="box infomessage" %) 139 139 ((( 140 -If the marking is too weak, we recommend checking the **Z-position in the job**, the** Z-position in the axis controls**, performing a new **Z-axis reference run and focusing and verifying the marking parameters**.138 +If the marking is too weak, we recommend checking the **Z-position in the job**, the** Z-position in the axis controls**, performing a new **Z-axis reference run and focusing and verifying the marking parameters**. 141 141 ))) 142 142 143 - **Also confirm that**:141 +Also confirm that: 144 144 145 145 * No fault messages are present 146 146 * Extraction is functioning correctly. ... ... @@ -168,17 +168,16 @@ 168 168 169 169 (% class="box infomessage" %) 170 170 ((( 171 -The High-Light includes software-controlled** X~/~/Y/Z axes**, with approximately **300 mm Z-axis travel** and approximately **460 x 260 mm X/Y travel**, so operators should understand axis movement and ensure that fixtures and workpieces cannot obstruct the required travel.169 +The High-Light includes software-controlled** X~/~/Y/Z axes**, with approximately **300 mm Z-axis travel** and approximately **460 x 260 mm X/Y travel**, so operators should understand axis movement and ensure that fixtures and workpieces cannot obstruct the required travel. 172 172 ))) 173 173 174 174 175 175 176 - 177 177 = Shutdown (End of Day) = 178 178 179 179 1. Finish the current marking operation. 180 180 1. Save the required marking project or parameters. 181 -1. Close** AnyMarker Designer** on the PC.178 +1. Close** AnyMarker Designer** on the PC. 182 182 1. Switch the High-Light off using the **main switch**. 183 183 1. Shut down the extraction system according to its operating instructions. 184 184 1. Leave the work chamber and surrounding area clean.