Changes for page Commissioning and First Start-Up
Last modified by jadomatis on 2026/08/31 10:15
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -8,7 +8,7 @@ 8 8 Important: Remove the protective cap from the laser objective before starting the laser.** 9 9 ))) 10 10 11 -= Preconditions(Before Switching On) =11 += Preconditions(Before Switching On) = 12 12 13 13 Confirm the following before applying power: 14 14 ... ... @@ -48,7 +48,7 @@ 48 48 49 49 = Software and Device Connection = 50 50 51 -1. Start** AnyMarker Designer** on the control PC.51 +1. Start** AnyMarker Designer** on the control PC. 52 52 1. Establish communication with High-Light controller. 53 53 1. Verify that the machine is connected and that no active fault prevents operation. 54 54 1. Confirm that the positioning/focus laser is available. During the startup sequence, two red laser points become visible once the system has initialized successfully. ... ... @@ -75,12 +75,12 @@ 75 75 76 76 Unlike the Multi-Light commissioning workflow, the High-Light requires a Z-axis reference run before normal operation. 77 77 78 -1. Perform a** reference movement of the Z-axis**.78 +1. Perform a** reference movement of the Z-axis**. 79 79 1. Create or open the required marking file. 80 80 1. Move the Z-axis to the required focusing height for the workpiece. 81 81 1. Verify the focus position before marking 82 82 83 -Correct focus is essential. The High-Light manual states that incorrect focusing is one of the most common causes of weak or completely invisible markings. The Z-axis should therefore be adjusted until the correct working distance between the marking head and the workpiece surface is achieved.83 +Correct focus is essential. Incorrect focusing is one of the most common causes of weak or completely invisible markings. The Z-axis should therefore be adjusted until the correct working distance between the marking head and the workpiece surface is achieved. 84 84 85 85 86 86 = Parameter Verification = ... ... @@ -135,10 +135,10 @@ 135 135 136 136 (% class="box infomessage" %) 137 137 ((( 138 -If the marking is too weak, we recommend checking the **Z-position in the job**, the** Z-position in the axis controls**, performing a new **Z-axis reference run and focusing and verifying the marking parameters**.138 +If the marking is too weak, we recommend checking the **Z-position in the job**, the** Z-position in the axis controls**, performing a new **Z-axis reference run and focusing and verifying the marking parameters**. 139 139 ))) 140 140 141 -Also confirm that: 141 +**Also confirm that**: 142 142 143 143 * No fault messages are present 144 144 * Extraction is functioning correctly. ... ... @@ -166,7 +166,7 @@ 166 166 167 167 (% class="box infomessage" %) 168 168 ((( 169 -The High-Light includes software-controlled** X~/~/Y/Z axes**, with approximately **300 mm Z-axis travel** and approximately **460 x 260 mm X/Y travel**, so operators should understand axis movement and ensure that fixtures and workpieces cannot obstruct the required travel.169 +The High-Light includes software-controlled** X~/~/Y/Z axes**, with approximately **300 mm Z-axis travel** and approximately **460 x 260 mm X/Y travel**, so operators should understand axis movement and ensure that fixtures and workpieces cannot obstruct the required travel. 170 170 ))) 171 171 172 172 ... ... @@ -175,7 +175,7 @@ 175 175 176 176 1. Finish the current marking operation. 177 177 1. Save the required marking project or parameters. 178 -1. Close** AnyMarker Designer** on the PC.178 +1. Close** AnyMarker Designer** on the PC. 179 179 1. Switch the High-Light off using the **main switch**. 180 180 1. Shut down the extraction system according to its operating instructions. 181 181 1. Leave the work chamber and surrounding area clean.