Zusammenfassung

Details

Seiteneigenschaften
Inhalt
... ... @@ -20,15 +20,4 @@
20 20  * The main switch is in the OFF position before connecting the power cable.
21 21  * The laser protection window is undamaged.
22 22  * Optical components are free from dust and contamination.
23 -* The protective cover has been removed from the focusing objective.
24 -* All required laser-safety measures have been implemented and verified.
25 -
26 -The operating environments must also meet the High-Light requirements:
27 -
28 -* Ambient temperature: +15 °C to +35 °C.
29 -* Relative humidity: maximum 90%, non condensing.
30 -* If the system has experienced significant temperature changes during transport, allow it to return to room temperature before commissioning.
31 -* Avoid shocks, vibration and other mechanical stress.
32 -* Keep the ventilation openings and filter areas of both 19" units unobstructed to prevent heat build-up.
33 -
34 -Suitable extraction must be available for the marking process. Laser processing can generate gases, vapors, aerosols and dust depending on the material and parameters. The operator is responsible for providing appropriate extraction to protect personne
23 +* The protective cover has been removed from the focusing objectiv