Änderungen von Dokument Commissioning and First Start-Up
Zuletzt geändert von jadomatis am 2026/08/31 10:15
Zusammenfassung
-
Seiteneigenschaften (1 geändert, 0 hinzugefügt, 0 gelöscht)
Details
- Seiteneigenschaften
-
- Inhalt
-
... ... @@ -12,23 +12,7 @@ 12 12 13 13 Confirm the following before applying power: 14 14 15 -* All packaging material has been removed. 16 -* All transport locks have been removed. 17 -* The High-Light is standing upright in its intended operation position. 18 -* Supply voltage and frequency have been checked against the machine requirements. 19 -* The mains cable and plug are undamaged. 20 -* The main switch is in the OFF position before connecting the power cable. 21 -* The laser protection window is undamaged. 22 -* Optical components are free from dust and contamination. 23 -* The protective cover has been removed from the focusing objective. 24 -* All required laser-safety measures have been implemented and verified. 25 - 26 -The operating environments must also meet the High-Light requirements: 27 - 28 -* Ambient temperature: +15 °C to +35 °C. 29 -* Relative humidity: maximum 90%, non condensing. 30 -* If the system has experienced significant temperature changes during transport, allow it to return to room temperature before commissioning. 31 -* Avoid shocks, vibration and other mechanical stress. 32 -* Keep the ventilation openings and filter areas of both 19" units unobstructed to prevent heat build-up. 33 - 34 -Suitable extraction must be available for the mar 15 +* All packaging material has been removed 16 +* All transport locks have been removed 17 +* The High-Light is standing upright in its intended operation position 18 +* Supply voltage and frequen