... ... @@ -81,13 +81,13 @@ 81 81 ))) 82 82 83 83 (% style="font-size:14px" %) (%%)The X1 emergency-stop connection uses two external safety channels. Circuit 1 is connected through X1.1/X1.2 and circuit 2 through X1.3/X1.4. The external safety module must validate both channels; a discrepancy belongs to the integrated safety chain, not to normal AnyMarker job handling. 84 - 84 +\\ 85 85 86 86 [[**Example: dual emergency-stop safety circuits at X1.1-X1.4.**>>image:1788775595167-399.png]] 87 87 88 88 89 - \\Emergency-stop acknowledgement is provided at X1.5/X1.6. At every system restart and after every emergency-stop actuation acknowledgement is required. If acknowledgement is not accepted, do not repeat the reset indefinitely; record the host safety state and escalate a recurring condition.90 - 89 +Emergency-stop acknowledgement is provided at X1.5/X1.6. At every system restart and after every emergency-stop actuation acknowledgement is required. If acknowledgement is not accepted, do not repeat the reset indefinitely; record the host safety state and escalate a recurring condition. 90 +\\ 91 91 92 92 [[**Example: emergency-stop acknowledgement at X1.5/X1.6.**>>image:1788775764610-963.png]] 93 93 ... ... @@ -101,7 +101,7 @@ 101 101 102 102 103 103 Shutter acknowledgement is provided at X1.11/X1.12. When SHUTTER status is missing, first verify the host guard and safety-module indications. A pin-level test or change to the acknowledgement circuit is an integration-service task. 104 - 104 +\\ 105 105 106 106 [[**Example: shutter acknowledgement at X1.11/X1.12.**>>image:1788776541211-163.png]] 107 107 ... ... @@ -237,5 +237,3 @@ 237 237 **service@schilling-marking.de** | **www.schilling-marking.de** 238 238 In Grubenaecker 1, 78532 Tuttlingen, Germany | **Fax +49 (07461) 9472-20** 239 239 ))) 240 - 241 -