83 83  (% style="font-size:14px" %) (%%)The X1 emergency-stop connection uses two external safety channels. Circuit 1 is connected through X1.1/X1.2 and circuit 2 through X1.3/X1.4. The external safety module must validate both channels; a discrepancy belongs to the integrated safety chain, not to normal AnyMarker job handling.
84 -
84 +\\
85 85  
86 86  [[**Example: dual emergency-stop safety circuits at X1.1-X1.4.**>>image:1788775595167-399.png]]
87 87  
88 88  
89 -\\Emergency-stop acknowledgement is provided at X1.5/X1.6. At every system restart  and after every emergency-stop actuation acknowledgement is required. If acknowledgement is not accepted, do not repeat the reset indefinitely; record the host safety state and escalate a recurring condition.
90 -
89 +Emergency-stop acknowledgement is provided at X1.5/X1.6. At every system restart  and after every emergency-stop actuation acknowledgement is required. If acknowledgement is not accepted, do not repeat the reset indefinitely; record the host safety state and escalate a recurring condition.
90 +\\
91 91  
92 92  [[**Example: emergency-stop acknowledgement at X1.5/X1.6.**>>image:1788775764610-963.png]]
93 93  
... ... @@ -101,7 +101,7 @@
101 101  
102 102  
103 103  Shutter acknowledgement is provided at X1.11/X1.12. When SHUTTER status is missing, first verify the host guard and safety-module indications. A pin-level test or change to the acknowledgement circuit is an integration-service task.
104 -
104 +\\
105 105  
106 106  [[**Example: shutter acknowledgement at X1.11/X1.12.**>>image:1788776541211-163.png]]
107 107  
... ... @@ -200,42 +200,14 @@
200 200   **Additional X2 pins: ** X2.17 is GND and X2.19 is the +5 V supply; the remaining listed pins are not connected. Voltage checks, connector work, and changes to axis wiring or configuration are service tasks for authorized personnel.
201 201  )))
202 202  
203 -
204 -
205 205  = Operator Checkpoints on the Laser Rack =
206 206  
205 +[[image:1788778758156-557.png]]
207 207  
208 -[[image:1788778838681-766.png]]
207 +//Figure 6 - External operator and connection points. Do not remove covers or open the laser rack.//
209 209  
210 -
211 211  * Check the rear main switch, front laser key switch, status indicator, and approved host/AnyMarker connection.
212 212  * Keep the cooling vents unobstructed. Stop operation if airflow is restricted, heat accumulates, or an abnormal smell or sound is present.
213 213  * Visually inspect accessible cables and connectors without opening covers or disturbing the validated wiring. Isolate and escalate damage, looseness, overheating, or contamination.
214 214  
215 -
216 -
217 -= Stop and Escalate =
218 -
219 -Stop troubleshooting, isolate the equipment, and contact authorised service personnel when:
220 -
221 -* a safety channel, shutter circuit, guard function, acknowledgement or emission warning cannot be verified;
222 -* the same fault returns after one approved reset, or LASER READY/BUSY/END behaves unpredictably;
223 -* internal electrical, optical, cooling, laser-source, controller, X1/X2 wiring, or mechanical-axis access is required;
224 -* an optic, cable, connector, enclosure, laser-protection window, fixture, or extraction component is damaged; or
225 -* the cause is uncertain or the corrective action is outside the person's training and authority.
226 -
227 -
228 -
229 -= Information for Schilling Service =
230 -
231 -Provide the serial number and exact Auto-Light model, AnyMarker version and job name, all host and laser messages, recorded X1 states, the event sequence, recent changes, and safe photographs or screenshots.
232 -
233 -(% class="box infomessage" %)
234 -(((
235 -**Schilling Service Centre**
236 -**+49 (07461) 9472-16**  |  Monday-Friday, 08:00-16:30
237 -**service@schilling-marking.de**  |  **www.schilling-marking.de**
238 -In Grubenaecker 1, 78532 Tuttlingen, Germany  |  **Fax +49 (07461) 9472-20**
239 -)))
240 -
241 241