... ... @@ -81,13 +81,13 @@
81 81  )))
82 82  
83 83  (% style="font-size:14px" %) (%%)The X1 emergency-stop connection uses two external safety channels. Circuit 1 is connected through X1.1/X1.2 and circuit 2 through X1.3/X1.4. The external safety module must validate both channels; a discrepancy belongs to the integrated safety chain, not to normal AnyMarker job handling.
84 -\\
84 +
85 85  
86 86  [[**Example: dual emergency-stop safety circuits at X1.1-X1.4.**>>image:1788775595167-399.png]]
87 87  
88 88  
89 -Emergency-stop acknowledgement is provided at X1.5/X1.6. At every system restart  and after every emergency-stop actuation acknowledgement is required. If acknowledgement is not accepted, do not repeat the reset indefinitely; record the host safety state and escalate a recurring condition.
90 -\\
89 +\\Emergency-stop acknowledgement is provided at X1.5/X1.6. At every system restart  and after every emergency-stop actuation acknowledgement is required. If acknowledgement is not accepted, do not repeat the reset indefinitely; record the host safety state and escalate a recurring condition.
90 +
91 91  
92 92  [[**Example: emergency-stop acknowledgement at X1.5/X1.6.**>>image:1788775764610-963.png]]
93 93  
... ... @@ -101,7 +101,7 @@
101 101  
102 102  
103 103  Shutter acknowledgement is provided at X1.11/X1.12. When SHUTTER status is missing, first verify the host guard and safety-module indications. A pin-level test or change to the acknowledgement circuit is an integration-service task.
104 -\\
104 +
105 105  
106 106  [[**Example: shutter acknowledgement at X1.11/X1.12.**>>image:1788776541211-163.png]]
107 107  
... ... @@ -237,3 +237,5 @@