195 195  * Axis will not reference: inspect the corresponding zero signal - X2.9 for X, X2.11 for Y, X2.13 for Z, or X2.15 for R - using the approved service procedure.
196 196  * Unexpected direction, travel, repeated reference failure, or mechanical obstruction: stop movement and isolate the system. Do not continue jogging the axis to overcome the condition.
197 197  
198 -(% class="box warningmessage" %)
199 -(((
200 - **Additional X2 pins: ** X2.17 is GND and X2.19 is the +5 V supply; the remaining listed pins are not connected. Voltage checks, connector work, and changes to axis wiring or configuration are service tasks for authorized personnel.
201 -)))
202 -
203 -
204 -
205 -= Operator Checkpoints on the Laser Rack =
206 -
207 -
208 -[[image:1788778838681-766.png]]
209 -
210 -
211 -* Check the rear main switch, front laser key switch, status indicator, and approved host/AnyMarker connection.
212 -* Keep the cooling vents unobstructed. Stop operation if airflow is restricted, heat accumulates, or an abnormal smell or sound is present.
213 -* Visually inspect accessible cables and connectors without opening covers or disturbing the validated wiring. Isolate and escalate damage, looseness, overheating, or contamination.
214 -
215 -
216 -
217 -= Stop and Escalate =
218 -
219 -Stop troubleshooting, isolate the equipment, and contact authorised service personnel when:
220 -
221 -* a safety channel, shutter circuit, guard function, acknowledgement or emission warning cannot be verified;
222 -* the same fault returns after one approved reset, or LASER READY/BUSY/END behaves unpredictably;
223 -* internal electrical, optical, cooling, laser-source, controller, X1/X2 wiring, or mechanical-axis access is required;
224 -* an optic, cable, connector, enclosure, laser-protection window, fixture, or extraction component is damaged; or
225 -* the cause is uncertain or the corrective action is outside the person's training and authority.
226 -
227 -
228 -
229 -= Information for Schilling Service =
230 -
231 -Provide the serial number and exact Auto-Light model, AnyMarker version and job name, all host and laser messages, recorded X1 states, the event sequence, recent changes, and safe photographs or screenshots.
232 -
233 -(% class="box infomessage" %)
234 -(((
235 -**Schilling Service Centre**
236 -**+49 (07461) 9472-16**  |  Monday-Friday, 08:00-16:30
237 -**service@schilling-marking.de**  |  **www.schilling-marking.de**
238 -In Grubenaecker 1, 78532 Tuttlingen, Germany  |  **Fax +49 (07461) 9472-20**
239 -)))
198 +
1788778758156-557.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.jadomatis
Größe
... ... @@ -1,1 +1,0 @@
1 -535.6 KB
Inhalt
1788778838681-766.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.jadomatis
Größe
... ... @@ -1,1 +1,0 @@
1 -216.4 KB
Inhalt