Änderungen von Dokument Troubleshooting
Zuletzt geändert von jadomatis am 2026/09/07 13:51
Zusammenfassung
-
Seiteneigenschaften (1 geändert, 0 hinzugefügt, 0 gelöscht)
Details
- Seiteneigenschaften
-
- Inhalt
-
... ... @@ -81,13 +81,13 @@ 81 81 ))) 82 82 83 83 (% style="font-size:14px" %) (%%)The X1 emergency-stop connection uses two external safety channels. Circuit 1 is connected through X1.1/X1.2 and circuit 2 through X1.3/X1.4. The external safety module must validate both channels; a discrepancy belongs to the integrated safety chain, not to normal AnyMarker job handling. 84 - \\84 + 85 85 86 86 [[**Example: dual emergency-stop safety circuits at X1.1-X1.4.**>>image:1788775595167-399.png]] 87 87 88 88 89 -Emergency-stop acknowledgement is provided at X1.5/X1.6. At every system restart and after every emergency-stop actuation acknowledgement is required. If acknowledgement is not accepted, do not repeat the reset indefinitely; record the host safety state and escalate a recurring condition. 90 - \\89 +\\Emergency-stop acknowledgement is provided at X1.5/X1.6. At every system restart and after every emergency-stop actuation acknowledgement is required. If acknowledgement is not accepted, do not repeat the reset indefinitely; record the host safety state and escalate a recurring condition. 90 + 91 91 92 92 [[**Example: emergency-stop acknowledgement at X1.5/X1.6.**>>image:1788775764610-963.png]] 93 93 ... ... @@ -101,7 +101,7 @@ 101 101 102 102 103 103 Shutter acknowledgement is provided at X1.11/X1.12. When SHUTTER status is missing, first verify the host guard and safety-module indications. A pin-level test or change to the acknowledgement circuit is an integration-service task. 104 - \\104 + 105 105 106 106 [[**Example: shutter acknowledgement at X1.11/X1.12.**>>image:1788776541211-163.png]] 107 107 ... ... @@ -212,4 +212,30 @@ 212 212 * Keep the cooling vents unobstructed. Stop operation if airflow is restricted, heat accumulates, or an abnormal smell or sound is present. 213 213 * Visually inspect accessible cables and connectors without opening covers or disturbing the validated wiring. Isolate and escalate damage, looseness, overheating, or contamination. 214 214 215 + 216 + 217 += Stop and Escalate = 218 + 219 +Stop troubleshooting, isolate the equipment, and contact authorised service personnel when: 220 + 221 +* a safety channel, shutter circuit, guard function, acknowledgement or emission warning cannot be verified; 222 +* the same fault returns after one approved reset, or LASER READY/BUSY/END behaves unpredictably; 223 +* internal electrical, optical, cooling, laser-source, controller, X1/X2 wiring, or mechanical-axis access is required; 224 +* an optic, cable, connector, enclosure, laser-protection window, fixture, or extraction component is damaged; or 225 +* the cause is uncertain or the corrective action is outside the person's training and authority. 226 + 227 + 228 + 229 += Information for Schilling Service = 230 + 231 +Provide the serial number and exact Auto-Light model, AnyMarker version and job name, all host and laser messages, recorded X1 states, the event sequence, recent changes, and safe photographs or screenshots. 232 + 233 +(% class="box infomessage" %) 234 +((( 235 +**Schilling Service Centre** 236 +**+49 (07461) 9472-16** | Monday-Friday, 08:00-16:30 237 +**service@schilling-marking.de** | **www.schilling-marking.de** 238 +In Grubenaecker 1, 78532 Tuttlingen, Germany | **Fax +49 (07461) 9472-20** 239 +))) 240 + 215 215