Änderungen von Dokument Troubleshooting
Zuletzt geändert von jadomatis am 2026/09/07 13:51
Zusammenfassung
-
Seiteneigenschaften (1 geändert, 0 hinzugefügt, 0 gelöscht)
Details
- Seiteneigenschaften
-
- Inhalt
-
... ... @@ -1,5 +1,7 @@ 1 1 **Description**: Learn how to identify common Auto-Light symptoms, verify the integration start conditions, and decide whether the fault is within the operator's authority or must be escalated. Auto-Light is a Class 4 integration laser, so the host machine's safeguards are part of every diagnosis. 2 2 3 +{{toc/}} 4 + 3 3 (% class="box errormessage" %) 4 4 ((( 5 5 **Safety first: **Never bypass a guard, emergency-stop channel, shutter circuit, acknowledgement circuit, emission warning, extraction interlock, or protective cover to test the laser. Maintenance and repair may be performed only by Schilling Marking Systems or authorised personnel in accordance with the site's safety procedure. ... ... @@ -64,6 +64,7 @@ 64 64 65 65 66 66 69 + 67 67 = AnyMarker or Controller Communication = 68 68 69 69 * Record the message before closing AnyMarker or restarting the controller. ... ... @@ -70,7 +70,7 @@ 70 70 * Confirm the approved USB or Ethernet connection and the expected Auto-Light device selection without disconnecting cables during an active cycle. 71 71 * If communication repeatedly drops, stop production and have the workstation, cable, controller and network path checked by authorised personnel. 72 72 73 -For software messages, device connection, and job handling, use the **[[AnyMarker Designer XWiki>>url:https://docs2.anymarker.de]]**. 76 +For software messages, device connection, and job handling, use the **[[AnyMarker Designer XWiki>>url:https://docs2.anymarker.de]]**. 74 74 75 75 76 76 = X1 Safety Interface - Emergency-Stop Circuit = ... ... @@ -81,13 +81,14 @@ 81 81 ))) 82 82 83 83 (% style="font-size:14px" %) (%%)The X1 emergency-stop connection uses two external safety channels. Circuit 1 is connected through X1.1/X1.2 and circuit 2 through X1.3/X1.4. The external safety module must validate both channels; a discrepancy belongs to the integrated safety chain, not to normal AnyMarker job handling. 84 - \\87 + 85 85 86 86 [[**Example: dual emergency-stop safety circuits at X1.1-X1.4.**>>image:1788775595167-399.png]] 87 87 88 88 92 + 89 89 Emergency-stop acknowledgement is provided at X1.5/X1.6. At every system restart and after every emergency-stop actuation acknowledgement is required. If acknowledgement is not accepted, do not repeat the reset indefinitely; record the host safety state and escalate a recurring condition. 90 - \\94 + 91 91 92 92 [[**Example: emergency-stop acknowledgement at X1.5/X1.6.**>>image:1788775764610-963.png]] 93 93 ... ... @@ -101,7 +101,7 @@ 101 101 102 102 103 103 Shutter acknowledgement is provided at X1.11/X1.12. When SHUTTER status is missing, first verify the host guard and safety-module indications. A pin-level test or change to the acknowledgement circuit is an integration-service task. 104 - \\108 + 105 105 106 106 [[**Example: shutter acknowledgement at X1.11/X1.12.**>>image:1788776541211-163.png]] 107 107 ... ... @@ -139,6 +139,7 @@ 139 139 140 140 141 141 146 + 142 142 = X2 Axis Interface = 143 143 144 144 X2 is the 25-pin Sub-D axis interface. Direction and step outputs for X, Y, Z, and R are grouped with zero/reference signals. Use this pinout to identify the affected axis and whether the symptom concerns commanded motion or the reference input; do not use it as an energized probing guide. ... ... @@ -202,6 +202,7 @@ 202 202 203 203 204 204 210 + 205 205 = Operator Checkpoints on the Laser Rack = 206 206 207 207 ... ... @@ -212,4 +212,30 @@ 212 212 * Keep the cooling vents unobstructed. Stop operation if airflow is restricted, heat accumulates, or an abnormal smell or sound is present. 213 213 * Visually inspect accessible cables and connectors without opening covers or disturbing the validated wiring. Isolate and escalate damage, looseness, overheating, or contamination. 214 214 221 + 222 + 223 += Stop and Escalate = 224 + 225 +Stop troubleshooting, isolate the equipment, and contact authorised service personnel when: 226 + 227 +* a safety channel, shutter circuit, guard function, acknowledgement or emission warning cannot be verified; 228 +* the same fault returns after one approved reset, or LASER READY/BUSY/END behaves unpredictably; 229 +* internal electrical, optical, cooling, laser-source, controller, X1/X2 wiring, or mechanical-axis access is required; 230 +* an optic, cable, connector, enclosure, laser-protection window, fixture, or extraction component is damaged; or 231 +* the cause is uncertain or the corrective action is outside the person's training and authority. 232 + 233 + 234 + 235 += Information for Schilling Service = 236 + 237 +Provide the serial number and exact Auto-Light model, AnyMarker version and job name, all host and laser messages, recorded X1 states, the event sequence, recent changes, and safe photographs or screenshots. 238 + 239 +(% class="box infomessage" %) 240 +((( 241 +**Schilling Service Centre** 242 +**+49 (07461) 9472-16** | Monday-Friday, 08:00-16:30 243 +**service@schilling-marking.de** | **www.schilling-marking.de** 244 +In Grubenaecker 1, 78532 Tuttlingen, Germany | **Fax +49 (07461) 9472-20** 245 +))) 246 + 215 215