200 200   **Additional X2 pins: ** X2.17 is GND and X2.19 is the +5 V supply; the remaining listed pins are not connected. Voltage checks, connector work, and changes to axis wiring or configuration are service tasks for authorized personnel.
201 201  )))
202 202  
203 +
204 +
203 203  = Operator Checkpoints on the Laser Rack =
204 204  
205 -[[image:1788778758156-557.png]]
206 206  
207 -//Figure 6 - External operator and connection points. Do not remove covers or open the laser rack.//
208 +[[image:1788778838681-766.png]]
208 208  
210 +
209 209  * Check the rear main switch, front laser key switch, status indicator, and approved host/AnyMarker connection.
210 210  * Keep the cooling vents unobstructed. Stop operation if airflow is restricted, heat accumulates, or an abnormal smell or sound is present.
211 211  * Visually inspect accessible cables and connectors without opening covers or disturbing the validated wiring. Isolate and escalate damage, looseness, overheating, or contamination.
212 212  
213 -
215 +
216 +
217 += Stop and Escalate =
218 +
219 +Stop troubleshooting, isolate the equipment, and contact authorised service personnel when:
220 +
221 +* a safety channel, shutter circuit, guard function, acknowledgement or emission warning cannot be verified;
222 +* the same fault returns after one approved reset, or LASER READY/BUSY/END behaves unpredictably;
223 +* internal electrical, optical, cooling, laser-source, controller, X1/X2 wiring, or mechanical-axis access is required;
224 +* an optic, cable, connector, enclosure, laser-protection window, fixture, or extraction component is damaged; or
225 +* the cause is uncertain or the corrective action is outside the person's training and authority.
226 +
227 +
228 +
229 += Information for Schilling Service =
230 +
231 +Provide the serial number and exact Auto-Light model, AnyMarker version and job name, all host and laser messages, recorded X1 states, the event sequence, recent changes, and safe photographs or screenshots.
232 +
233 +(% class="box infomessage" %)
234 +(((
235 +**Schilling Service Centre**
236 +**+49 (07461) 9472-16**  |  Monday-Friday, 08:00-16:30
237 +**service@schilling-marking.de**  |  **www.schilling-marking.de**
238 +In Grubenaecker 1, 78532 Tuttlingen, Germany  |  **Fax +49 (07461) 9472-20**
239 +)))